WEKO3
アイテム
{"_buckets": {"deposit": "84d3b568-a7f8-4be6-a5be-a724d94dec65"}, "_deposit": {"created_by": 3, "id": "10210", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "10210"}, "status": "published"}, "_oai": {"id": "oai:nifs-repository.repo.nii.ac.jp:00010210", "sets": ["32"]}, "author_link": ["64249", "64247", "64248", "64246"], "item_5_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2004-03-01", "bibliographicIssueDateType": "Issued"}, "bibliographic_titles": [{}, {"bibliographic_title": "Research Report NIFS-Series", "bibliographic_titleLang": "en"}]}]}, "item_5_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "\"The article discusses feasibility of magnetic fluctuation measurement with a heavy ion beam probe (HIBP) in an axisymmetric torus configuration. In the measurements, path integral fluctuation along the probing beam orbit should be considered as is similar to the density fluctuation measurements with HIBP.A calculation, based on an analytic formula, is performed to estimate the path integral effects for fluctuation patterns that have difference in profile, the correlation length, the radial wavelength, and the poloidal mode number. In addition, the large distance between the plasma and the detector is considered to lessen the path integral effect. As a result, it is found that local fluctuation of magnetic field can be properly detected with a heavy ion beam probe.\"", "subitem_description_type": "Abstract"}]}, "item_5_source_id_10": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0915-633X", "subitem_source_identifier_type": "ISSN"}]}, "item_5_text_25": {"attribute_name": "登録情報", "attribute_value_mlt": [{"subitem_text_value": "Made available in DSpace on 2010-02-05T10:19:46Z (GMT). No. of bitstreams: 0\n Previous issue date: 2004-03"}]}, "item_5_text_8": {"attribute_name": "報告書番号", "attribute_value_mlt": [{"subitem_text_value": "NIFS-796"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "\"Shimizu, A.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "64246", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Fujisawa, A.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "64247", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ohshima, S.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "64248", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nakano, H.\"", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "64249", "nameIdentifierScheme": "WEKO"}]}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Heavy Ion Beam Probe (HIBP)", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "magnetic field fluctuation", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "path integral effect", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "torus plasma", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "research report", "resourceuri": "http://purl.org/coar/resource_type/c_18ws"}]}, "item_title": "Consideration of Magnetic Field Fluctuation Measurements in a Torus Plasma with Heavy Ion Beam Probe", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Consideration of Magnetic Field Fluctuation Measurements in a Torus Plasma with Heavy Ion Beam Probe", "subitem_title_language": "en"}]}, "item_type_id": "5", "owner": "3", "path": ["32"], "permalink_uri": "http://hdl.handle.net/10655/3094", "pubdate": {"attribute_name": "公開日", "attribute_value": "2010-02-05"}, "publish_date": "2010-02-05", "publish_status": "0", "recid": "10210", "relation": {}, "relation_version_is_last": true, "title": ["Consideration of Magnetic Field Fluctuation Measurements in a Torus Plasma with Heavy Ion Beam Probe"], "weko_shared_id": -1}
Consideration of Magnetic Field Fluctuation Measurements in a Torus Plasma with Heavy Ion Beam Probe
http://hdl.handle.net/10655/3094
http://hdl.handle.net/10655/30940efcd712-7b85-4543-bae8-cce359ea9820
Item type | 研究報告書 / Research Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2010-02-05 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Consideration of Magnetic Field Fluctuation Measurements in a Torus Plasma with Heavy Ion Beam Probe | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Heavy Ion Beam Probe (HIBP) | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | magnetic field fluctuation | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | path integral effect | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | torus plasma | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_18ws | |||||
資源タイプ | research report | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
"Shimizu, A.
× "Shimizu, A.× Fujisawa, A.× Ohshima, S.× Nakano, H." |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | "The article discusses feasibility of magnetic fluctuation measurement with a heavy ion beam probe (HIBP) in an axisymmetric torus configuration. In the measurements, path integral fluctuation along the probing beam orbit should be considered as is similar to the density fluctuation measurements with HIBP.A calculation, based on an analytic formula, is performed to estimate the path integral effects for fluctuation patterns that have difference in profile, the correlation length, the radial wavelength, and the poloidal mode number. In addition, the large distance between the plasma and the detector is considered to lessen the path integral effect. As a result, it is found that local fluctuation of magnetic field can be properly detected with a heavy ion beam probe." | |||||
書誌情報 |
en : Research Report NIFS-Series 発行日 2004-03-01 |
|||||
報告書番号 | ||||||
NIFS-796 | ||||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0915-633X |