WEKO3
アイテム
{"_buckets": {"deposit": "3d5af982-d918-411c-9c1d-3a7f1fbb648d"}, "_deposit": {"created_by": 19, "id": "10845", "owners": [19], "pid": {"revision_id": 0, "type": "depid", "value": "10845"}, "status": "published"}, "_oai": {"id": "oai:nifs-repository.repo.nii.ac.jp:00010845", "sets": ["7"]}, "author_link": ["126775", "122527", "126772", "126773", "126774", "126769", "126771", "126770", "66882", "123136"], "item_10001_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2016-11-14", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "11", "bibliographicPageStart": "11D410", "bibliographicVolumeNumber": "87", "bibliographic_titles": [{"bibliographic_title": "Review of Scientific Instruments"}]}]}, "item_10001_description_4": {"attribute_name": "著者ID", "attribute_value_mlt": [{"subitem_description": "0000-0002-4446-4603", "subitem_description_type": "Other"}]}, "item_10001_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The infrared imaging video bolometer (IRVB) measures plasma radiated power images using a thin metal foil. Two different designs with a tangential view of NSTX-U are made assuming a 640 × 480 (1280 × 1024) pixel, 30 (105) fps, 50 (20) mK, IR camera imaging the 9 cm × 9 cm × 2 μm Pt foil. The foil is divided into 40 × 40 (64 × 64) IRVB channels. This gives a spatial resolution of 3.4 (2.2) cm on the machine mid-plane. The noise equivalent power density of the IRVB is given as 113 (46) μW/cm2 for a time resolution of 33 (20) ms. Synthetic images derived from Scrape Off Layer Plasma Simulation data using the IRVB geometry show peak signal levels ranging from ∼0.8 to ∼80 (∼0.36 to ∼26) mW/cm2.", "subitem_description_type": "Abstract"}]}, "item_10001_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "AIP Publishing"}]}, "item_10001_relation_13": {"attribute_name": "PubMed番号", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "27910451", "subitem_relation_type_select": "PMID"}}]}, "item_10001_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1063/1.4955278", "subitem_relation_type_select": "DOI"}}]}, "item_10001_relation_16": {"attribute_name": "情報源", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "Review of Scientific Instruments 87, 11D410 (2016); https://doi.org/10.1063/1.4955278"}]}]}, "item_10001_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "Publisher version"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1063/1.4955278", "subitem_relation_type_select": "DOI"}}]}, "item_10001_rights_15": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "This article may be downloaded for personal use only. Any other use requires prior permission of the author and AIP Publishing. This article appeared in Review of Scientific Instruments 87, 11D410 (2016) and may be found at https://aip.scitation.org/doi/abs/10.1063/1.4955278."}, {"subitem_rights": "Copyright 2016 Author(s). This article is distributed under a Creative Commons Attribution (CC BY) License. "}]}, "item_10001_source_id_11": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AA00817730", "subitem_source_identifier_type": "NCID"}]}, "item_10001_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "00346748", "subitem_source_identifier_type": "ISSN"}]}, "item_10001_text_23": {"attribute_name": "NAIS", "attribute_value_mlt": [{"subitem_text_value": "|||"}]}, "item_10001_version_type_20": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorAffiliations": [{"affiliationNameIdentifiers": [{"affiliationNameIdentifier": "", "affiliationNameIdentifierScheme": "ISNI", "affiliationNameIdentifierURI": "http://www.isni.org/isni/"}], "affiliationNames": [{"affiliationName": "", "affiliationNameLang": "ja"}]}], "creatorNames": [{"creatorName": "PETERSON, Byron", "creatorNameLang": "en"}, {"creatorName": "PETERSON, Byron J.", "creatorNameLang": "en"}], "familyNames": [{"familyName": "PETERSON", "familyNameLang": "en"}, {"familyName": "PETERSON", "familyNameLang": "en"}], "givenNames": [{"givenName": " Byron", "givenNameLang": "en"}, {"givenName": " Byron J.", "givenNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "66882", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "SANO, Ryuichi"}], "nameIdentifiers": [{"nameIdentifier": "123136", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Reinke, M.L."}], "nameIdentifiers": [{"nameIdentifier": "126769", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Canik, J.M."}], "nameIdentifiers": [{"nameIdentifier": "126770", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Delgado-Aparicio, L.F."}], "nameIdentifiers": [{"nameIdentifier": "126771", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Lore, J.D."}], "nameIdentifiers": [{"nameIdentifier": "126772", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Mukai, Kiyofumi"}], "nameIdentifiers": [{"nameIdentifier": "122527", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Gray, T.K."}], "nameIdentifiers": [{"nameIdentifier": "126773", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Eden, G.G. van"}], "nameIdentifiers": [{"nameIdentifier": "126774", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Jaworski, M.A."}], "nameIdentifiers": [{"nameIdentifier": "126775", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2021-12-22"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "Rev.Sci.Instrum.87_pp11D410.pdf", "filesize": [{"value": "330.3 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_6", "mimetype": "application/pdf", "size": 330300.0, "url": {"label": "Rev.Sci.Instrum.87_pp11D410", "url": "https://nifs-repository.repo.nii.ac.jp/record/10845/files/Rev.Sci.Instrum.87_pp11D410.pdf"}, "version_id": "1c1675a9-bb8c-4e44-8d17-7cc6dfcd3696"}, {"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2022-03-16"}], "displaytype": "detail", "download_preview_message": "", "file_order": 1, "filename": "VoR_Rev.Sci.Instrum8_11D410.pdf", "filesize": [{"value": "2.4 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_11", "mimetype": "application/pdf", "size": 2400000.0, "url": {"label": "VoR_Rev.Sci.Instrum8_11D410", "url": "https://nifs-repository.repo.nii.ac.jp/record/10845/files/VoR_Rev.Sci.Instrum8_11D410.pdf"}, "version_id": "a6399ee2-bb02-44d5-a7a9-c5cbb2168510"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Preliminary design of a tangentially viewing imaging bolometer for NSTX-U", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Preliminary design of a tangentially viewing imaging bolometer for NSTX-U"}]}, "item_type_id": "10001", "owner": "19", "path": ["7"], "permalink_uri": "http://hdl.handle.net/10655/00012813", "pubdate": {"attribute_name": "公開日", "attribute_value": "2021-12-22"}, "publish_date": "2021-12-22", "publish_status": "0", "recid": "10845", "relation": {}, "relation_version_is_last": true, "title": ["Preliminary design of a tangentially viewing imaging bolometer for NSTX-U"], "weko_shared_id": 19}
Preliminary design of a tangentially viewing imaging bolometer for NSTX-U
http://hdl.handle.net/10655/00012813
http://hdl.handle.net/10655/00012813c04525ab-6c68-4d25-8780-d9e6571ade31
名前 / ファイル | ライセンス | アクション |
---|---|---|
Rev.Sci.Instrum.87_pp11D410 (330.3 kB)
|
||
VoR_Rev.Sci.Instrum8_11D410 (2.4 MB)
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2021-12-22 | |||||
タイトル | ||||||
タイトル | Preliminary design of a tangentially viewing imaging bolometer for NSTX-U | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
PETERSON, Byron
× PETERSON, Byron× SANO, Ryuichi× Reinke, M.L.× Canik, J.M.× Delgado-Aparicio, L.F.× Lore, J.D.× Mukai, Kiyofumi× Gray, T.K.× Eden, G.G. van× Jaworski, M.A. |
|||||
著者ID | ||||||
内容記述タイプ | Other | |||||
内容記述 | 0000-0002-4446-4603 | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The infrared imaging video bolometer (IRVB) measures plasma radiated power images using a thin metal foil. Two different designs with a tangential view of NSTX-U are made assuming a 640 × 480 (1280 × 1024) pixel, 30 (105) fps, 50 (20) mK, IR camera imaging the 9 cm × 9 cm × 2 μm Pt foil. The foil is divided into 40 × 40 (64 × 64) IRVB channels. This gives a spatial resolution of 3.4 (2.2) cm on the machine mid-plane. The noise equivalent power density of the IRVB is given as 113 (46) μW/cm2 for a time resolution of 33 (20) ms. Synthetic images derived from Scrape Off Layer Plasma Simulation data using the IRVB geometry show peak signal levels ranging from ∼0.8 to ∼80 (∼0.36 to ∼26) mW/cm2. | |||||
書誌情報 |
Review of Scientific Instruments 巻 87, 号 11, p. 11D410, 発行日 2016-11-14 |
|||||
出版者 | ||||||
出版者 | AIP Publishing | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 00346748 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA00817730 | |||||
PubMed番号 | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | PMID | |||||
関連識別子 | 27910451 | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1063/1.4955278 | |||||
権利 | ||||||
権利情報 | This article may be downloaded for personal use only. Any other use requires prior permission of the author and AIP Publishing. This article appeared in Review of Scientific Instruments 87, 11D410 (2016) and may be found at https://aip.scitation.org/doi/abs/10.1063/1.4955278. | |||||
権利 | ||||||
権利情報 | Copyright 2016 Author(s). This article is distributed under a Creative Commons Attribution (CC BY) License. | |||||
情報源 | ||||||
関連名称 | Review of Scientific Instruments 87, 11D410 (2016); https://doi.org/10.1063/1.4955278 | |||||
関連サイト | ||||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1063/1.4955278 | |||||
関連名称 | Publisher version | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
NAIS | ||||||
||| |