{"_buckets": {"deposit": "324f7c18-9a5e-4c81-af38-2b75392242e8"}, "_deposit": {"created_by": 21, "id": "11066", "owners": [21], "pid": {"revision_id": 0, "type": "depid", "value": "11066"}, "status": "published"}, "_oai": {"id": "oai:nifs-repository.repo.nii.ac.jp:00011066", "sets": ["7"]}, "author_link": ["67651", "126699", "66901", "66841", "126606", "66751", "126698", "66548", "67537"], "item_10001_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2022-01", "bibliographicIssueDateType": "Issued"}, "bibliographicPageStart": "C01016", "bibliographicVolumeNumber": "17", "bibliographic_titles": [{"bibliographic_title": "Journal of Instrumentation "}]}]}, "item_10001_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "In this study, we developed the Electron Cyclotron Emission Imaging (ECEI) system with the Q-band in the Large Helical Device (LHD). ECEI measurement makes it possible to obtain the spatiotemporal structure of magnetohydrodynamics (MHD) instabilities in the high-β plasma. Although there were several difficulties for realizing the multi-channelization, such as local oscillator (LO) optics and an expensive high-power LO source, we have solved these problems by developing a Local Integrated Antenna array (LIA) which has an internal LO supply, using a frequency doubler integrated circuit on each channel, instead of a conventional Horn-antenna Mixer Array (HMA) with common LOs. In addition, we have made some improvements to enhance the quality of the measurement signal. First, we developed and introduced notch filters that prevent the strong Electron Cyclotron Resonance Heating (ECRH) stray signal from being mixed into the measurement circuit. Second, the position of the doubler built in the printed circuit board was reconsidered to prevent the mixing of higher harmonic components into the mixer. Also, we have adopted the Logarithmic detector (LOG detector) to deal with the wide dynamic range of the plasma fluctuation. After these improvements, for the first time, we could successfully obtain the initial results of the two-dimensional temperature distribution and its fluctuation distribution in the LHD.", "subitem_description_type": "Abstract"}]}, "item_10001_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "IOP Publishing "}]}, "item_10001_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1088/1748-0221/17/01/C01016", "subitem_relation_type_select": "DOI"}}]}, "item_10001_relation_16": {"attribute_name": "情報源", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "Y. Goto et al 2022 JINST 17 C01016"}]}]}, "item_10001_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "Publisher version"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1088/1748-0221/17/01/C01016", "subitem_relation_type_select": "DOI"}}]}, "item_10001_rights_15": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "This is the Accepted Manuscript version of an article accepted for publication in Journal of Instrumentation. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The Version of Record is available online at doi.org/10.1088/1748-0221/17/01/C01016. "}]}, "item_10001_source_id_11": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AA12456425 ", "subitem_source_identifier_type": "NCID"}]}, "item_10001_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "17480221 ", "subitem_source_identifier_type": "ISSN"}]}, "item_10001_text_23": {"attribute_name": "NAIS", "attribute_value_mlt": [{"subitem_text_value": "13126"}]}, "item_10001_text_25": {"attribute_name": "書誌的事項", "attribute_value_mlt": [{"subitem_text_value": "4 th European Conference on Plasma Diagnostics (ECPD2021) 7–11 June, 2021 Online"}]}, "item_10001_version_type_20": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_ab4af688f83e57aa", "subitem_version_type": "AM"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "GOTO, Yuki"}], "nameIdentifiers": [{"nameIdentifier": "126606", "nameIdentifierScheme": "WEKO"}]}, {"creatorAffiliations": [{"affiliationNameIdentifiers": [{"affiliationNameIdentifier": "", "affiliationNameIdentifierScheme": "ISNI", "affiliationNameIdentifierURI": "http://www.isni.org/isni/"}], "affiliationNames": [{"affiliationName": "", "affiliationNameLang": "ja"}]}], "creatorNames": [{"creatorName": "TOKUZAWA, Tokihiko", "creatorNameLang": "en"}], "familyNames": [{"familyName": "TOKUZAWA", "familyNameLang": "en"}], "givenNames": [{"givenName": " Tokihiko", "givenNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "66901", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kuwahara, D."}], "nameIdentifiers": [{"nameIdentifier": "67537", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ichinose, K."}], "nameIdentifiers": [{"nameIdentifier": "126699", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "TSUCHIYA, H."}], "nameIdentifiers": [{"nameIdentifier": "67651", "nameIdentifierScheme": "WEKO"}]}, {"creatorAffiliations": [{"affiliationNameIdentifiers": [{"affiliationNameIdentifier": "", "affiliationNameIdentifierScheme": "ISNI", "affiliationNameIdentifierURI": "http://www.isni.org/isni/"}], "affiliationNames": [{"affiliationName": "", "affiliationNameLang": "ja"}]}], "creatorNames": [{"creatorName": "NISHIURA, Masaki", "creatorNameLang": "en"}], "familyNames": [{"familyName": "NISHIURA", "familyNameLang": "en"}], "givenNames": [{"givenName": " Masaki", "givenNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "66751", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "SHIMIZU, T."}], "nameIdentifiers": [{"nameIdentifier": "126698", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "KUBO, S."}], "nameIdentifiers": [{"nameIdentifier": "66841", "nameIdentifierScheme": "WEKO"}]}, {"creatorAffiliations": [{"affiliationNameIdentifiers": [{"affiliationNameIdentifier": "", "affiliationNameIdentifierScheme": "ISNI", "affiliationNameIdentifierURI": "http://www.isni.org/isni/"}], "affiliationNames": [{"affiliationName": "", "affiliationNameLang": "ja"}]}], "creatorNames": [{"creatorName": "YAMADA, Ichihiro", "creatorNameLang": "en"}], "familyNames": [{"familyName": "YAMADA", "familyNameLang": "en"}], "givenNames": [{"givenName": " Ichihiro", "givenNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "66548", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2023-01-05"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "J.Instrumentation_17_C01016.pdf", "filesize": [{"value": "6.0 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_6", "mimetype": "application/pdf", "size": 6000000.0, "url": {"label": "J.Instrumentation_17_C01016", "url": "https://nifs-repository.repo.nii.ac.jp/record/11066/files/J.Instrumentation_17_C01016.pdf"}, "version_id": "cb9e017e-566f-4a47-b336-4d432aa0c375"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Detector design and construction technologies and materials", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Microwave Antennas", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Microwave radiometers", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Plasma diagnostics — interferometry", "subitem_subject_scheme": "Other"}, {"subitem_subject": "spectroscopy and imaging", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Development of the Q-band ECE imaging system in the large helical device", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Development of the Q-band ECE imaging system in the large helical device"}]}, "item_type_id": "10001", "owner": "21", "path": ["7"], "permalink_uri": "http://hdl.handle.net/10655/00013021", "pubdate": {"attribute_name": "公開日", "attribute_value": "2022-02-15"}, "publish_date": "2022-02-15", "publish_status": "0", "recid": "11066", "relation": {}, "relation_version_is_last": true, "title": ["Development of the Q-band ECE imaging system in the large helical device"], "weko_shared_id": 21}
Development of the Q-band ECE imaging system in the large helical device
http://hdl.handle.net/10655/00013021
http://hdl.handle.net/10655/0001302137878fc6-cf31-40fa-9e2d-8abe1063ae2d
名前 / ファイル | ライセンス | アクション |
---|---|---|
J.Instrumentation_17_C01016 (6.0 MB)
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2022-02-15 | |||||
タイトル | ||||||
タイトル | Development of the Q-band ECE imaging system in the large helical device | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Detector design and construction technologies and materials | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Microwave Antennas | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Microwave radiometers | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Plasma diagnostics — interferometry | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | spectroscopy and imaging | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
GOTO, Yuki
× GOTO, Yuki× TOKUZAWA, Tokihiko× Kuwahara, D.× Ichinose, K.× TSUCHIYA, H.× NISHIURA, Masaki× SHIMIZU, T.× KUBO, S.× YAMADA, Ichihiro |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | In this study, we developed the Electron Cyclotron Emission Imaging (ECEI) system with the Q-band in the Large Helical Device (LHD). ECEI measurement makes it possible to obtain the spatiotemporal structure of magnetohydrodynamics (MHD) instabilities in the high-β plasma. Although there were several difficulties for realizing the multi-channelization, such as local oscillator (LO) optics and an expensive high-power LO source, we have solved these problems by developing a Local Integrated Antenna array (LIA) which has an internal LO supply, using a frequency doubler integrated circuit on each channel, instead of a conventional Horn-antenna Mixer Array (HMA) with common LOs. In addition, we have made some improvements to enhance the quality of the measurement signal. First, we developed and introduced notch filters that prevent the strong Electron Cyclotron Resonance Heating (ECRH) stray signal from being mixed into the measurement circuit. Second, the position of the doubler built in the printed circuit board was reconsidered to prevent the mixing of higher harmonic components into the mixer. Also, we have adopted the Logarithmic detector (LOG detector) to deal with the wide dynamic range of the plasma fluctuation. After these improvements, for the first time, we could successfully obtain the initial results of the two-dimensional temperature distribution and its fluctuation distribution in the LHD. | |||||
書誌情報 |
Journal of Instrumentation 巻 17, p. C01016, 発行日 2022-01 |
|||||
書誌的事項 | ||||||
4 th European Conference on Plasma Diagnostics (ECPD2021) 7–11 June, 2021 Online | ||||||
出版者 | ||||||
出版者 | IOP Publishing | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 17480221 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA12456425 | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1088/1748-0221/17/01/C01016 | |||||
権利 | ||||||
権利情報 | This is the Accepted Manuscript version of an article accepted for publication in Journal of Instrumentation. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The Version of Record is available online at doi.org/10.1088/1748-0221/17/01/C01016. | |||||
情報源 | ||||||
関連名称 | Y. Goto et al 2022 JINST 17 C01016 | |||||
関連サイト | ||||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1088/1748-0221/17/01/C01016 | |||||
関連名称 | Publisher version | |||||
著者版フラグ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa | |||||
NAIS | ||||||
13126 |