{"_buckets": {"deposit": "1d412a3e-3f39-4ea4-9ff7-2251550ef0e6"}, "_deposit": {"created_by": 3, "id": "9869", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "9869"}, "status": "published"}, "_oai": {"id": "oai:nifs-repository.repo.nii.ac.jp:00009869", "sets": ["32"]}, "author_link": ["60168", "60162", "60167", "60170", "60163", "60171", "60165", "60164", "60166", "60169", "60161"], "item_5_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1996-03-01", "bibliographicIssueDateType": "Issued"}, "bibliographic_titles": [{}, {"bibliographic_title": "Research Report NIFS-Series", "bibliographic_titleLang": "en"}]}]}, "item_5_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Poloidail and radial magnetic field fluctuations less than 100 kHz are measured with a newly developed movable magnetic probe array in the JIPP T-IIU tokamak. The probe array protected by a carbon/carbon - composite with 20% boron is inserted beyond the last closed flux surface (LCFS) up to r/a simeq 0.77 without deleterious effect on ohmically and neutral beam heated plasmas. From the radial variation of the fluctuation amplitude just outside LCFS the poloidal mode number is estimated to be m leq 4 for low frequency coherent part (f \u003c 30kHz) and m~10 for relatively high frequency incoherent one (f \u003e 50kHz)", "subitem_description_type": "Abstract"}]}, "item_5_source_id_10": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0915-633X", "subitem_source_identifier_type": "ISSN"}]}, "item_5_text_25": {"attribute_name": "登録情報", "attribute_value_mlt": [{"subitem_text_value": "Made available in DSpace on 2010-02-05T10:17:02Z (GMT). No. of bitstreams: 0\n Previous issue date: 1996-03"}]}, "item_5_text_8": {"attribute_name": "報告書番号", "attribute_value_mlt": [{"subitem_text_value": "NIFS-407"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "\"Kitachi, K.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "60161", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Oike, T.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "60162", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ohdachi, S.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "60163", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Toi, K.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "60164", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Akiyama, R.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "60165", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ejiri, A.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "60166", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hamada, Y.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "60167", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kuramoto, H.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "60168", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Narihara, K.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "60169", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Seki, T.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "60170", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "JIPP, T-IIU Group\"", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "60171", "nameIdentifierScheme": "WEKO"}]}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Tokamak plasma", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Movable Magnetic Probe Array", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Magnetic Fluctuations", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Coherence", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Poloidal Mode Number", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "research report", "resourceuri": "http://purl.org/coar/resource_type/c_18ws"}]}, "item_title": "Measurement of Magnetic Field Fluctuations within Last Closed Flux Surface with Movable Magnetic Probe Array in the JIPP T-IIU Tokamak", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Measurement of Magnetic Field Fluctuations within Last Closed Flux Surface with Movable Magnetic Probe Array in the JIPP T-IIU Tokamak", "subitem_title_language": "en"}]}, "item_type_id": "5", "owner": "3", "path": ["32"], "permalink_uri": "http://hdl.handle.net/10655/2547", "pubdate": {"attribute_name": "公開日", "attribute_value": "2010-02-05"}, "publish_date": "2010-02-05", "publish_status": "0", "recid": "9869", "relation": {}, "relation_version_is_last": true, "title": ["Measurement of Magnetic Field Fluctuations within Last Closed Flux Surface with Movable Magnetic Probe Array in the JIPP T-IIU Tokamak"], "weko_shared_id": -1}
Measurement of Magnetic Field Fluctuations within Last Closed Flux Surface with Movable Magnetic Probe Array in the JIPP T-IIU Tokamak
http://hdl.handle.net/10655/2547
http://hdl.handle.net/10655/2547dbebdda5-8984-4149-8d1a-af0b56249708
Item type | 研究報告書 / Research Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2010-02-05 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Measurement of Magnetic Field Fluctuations within Last Closed Flux Surface with Movable Magnetic Probe Array in the JIPP T-IIU Tokamak | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Tokamak plasma | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Movable Magnetic Probe Array | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Magnetic Fluctuations | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Coherence | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Poloidal Mode Number | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_18ws | |||||
資源タイプ | research report | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
"Kitachi, K.
× "Kitachi, K.× Oike, T.× Ohdachi, S.× Toi, K.× Akiyama, R.× Ejiri, A.× Hamada, Y.× Kuramoto, H.× Narihara, K.× Seki, T.× JIPP, T-IIU Group" |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Poloidail and radial magnetic field fluctuations less than 100 kHz are measured with a newly developed movable magnetic probe array in the JIPP T-IIU tokamak. The probe array protected by a carbon/carbon - composite with 20% boron is inserted beyond the last closed flux surface (LCFS) up to r/a simeq 0.77 without deleterious effect on ohmically and neutral beam heated plasmas. From the radial variation of the fluctuation amplitude just outside LCFS the poloidal mode number is estimated to be m leq 4 for low frequency coherent part (f < 30kHz) and m~10 for relatively high frequency incoherent one (f > 50kHz) | |||||
書誌情報 |
en : Research Report NIFS-Series 発行日 1996-03-01 |
|||||
報告書番号 | ||||||
NIFS-407 | ||||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0915-633X |