H- Ion Source Using a Localized Virtual Magnetic Filter in the Plasma Electrode: Type I LV Magnetic Filter

http://hdl.handle.net/10655/2635
http://hdl.handle.net/10655/2635
5e1724d1-2c1b-4956-be1a-13b156026fc4
Item type 研究報告書 / Research Paper(1)
公開日 2010-02-05
タイトル
タイトル H- Ion Source Using a Localized Virtual Magnetic Filter in the Plasma Electrode: Type I LV Magnetic Filter
言語 en
言語
言語 eng
キーワード
言語 en
主題Scheme Other
主題 hydrogen negative ion
キーワード
言語 en
主題Scheme Other
主題 ion source
キーワード
言語 en
主題Scheme Other
主題 magnetic filter
キーワード
言語 en
主題Scheme Other
主題 cesium deposition
キーワード
言語 en
主題Scheme Other
主題 NBI
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_18ws
資源タイプ research report
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 "Oka, Y.

× "Oka, Y.

en "Oka, Y.

Search repository
Kaneko, O.

× Kaneko, O.

en Kaneko, O.

Search repository
Tsumori, K.

× Tsumori, K.

en Tsumori, K.

Search repository
Takeiri, Y.

× Takeiri, Y.

en Takeiri, Y.

Search repository
Osakabe, M.

× Osakabe, M.

en Osakabe, M.

Search repository
Kawamoto, T.

× Kawamoto, T.

en Kawamoto, T.

Search repository
Asano, E.

× Asano, E.

en Asano, E.

Search repository
Akiyama, R."

× Akiyama, R."

en Akiyama, R."

Search repository
抄録
内容記述タイプ Abstract
内容記述 "A new multicusp H^- ion source using a Localized Virtual magnetic filter of type I [Ref.6] in the plasma electrode is investigated. A multipole (MP) arrangement with a spacing of 10 mm of the magnet bars holds an extraction hole, optimizing the efficient production of high H^- current, and at the same time only a small electron component was co-extracted with the H^- ions. The local filter arrangement separates the beam electrons at a low energy. It is shown that the co-extracted total electron current is determined principally by the integrated magnetic field flux (Gcm) of the local filter with an extraction system at a constant extraction voltage. When the value of the Gcm is increased, the total electron component is reduced, while the H^- electrical efficiency had a braod maximum around the optimized value of the Gcm. A thicker plasma electrode should be necessary for sufficient reduction of electron current. In pure hydrogen operation, the achieved current density of H^- is 10 mA/cm^2. when Cs was seeded in a filter optimized for pure volume mode H^- production, the maximum H^- current density obtained is 51 mA/cm^2 and the ratio I_ele/H^- is ~ 0.4 without applying a bias potential."
書誌情報 en : Research Report NIFS-Series

発行日 1999-12-01
報告書番号
NIFS-622
ISSN
収録物識別子タイプ ISSN
収録物識別子 0915-633X
戻る
0
views
See details
Views

Versions

Ver.1 2023-06-20 20:53:31.341977
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

"Oka, Y., Kaneko, O., Tsumori, K., Takeiri, Y., Osakabe, M., Kawamoto, T., Asano, E., Akiyama, R.", 1999, H- Ion Source Using a Localized Virtual Magnetic Filter in the Plasma Electrode: Type I LV Magnetic Filter.