{"_buckets": {"deposit": "c9badd83-d2dd-40bd-b64d-7e7f14e25b9f"}, "_deposit": {"created_by": 3, "id": "10110", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "10110"}, "status": "published"}, "_oai": {"id": "oai:nifs-repository.repo.nii.ac.jp:00010110", "sets": ["32"]}, "author_link": ["63087", "63085", "63088", "63091", "63082", "63089", "63090", "63084", "63083", "63086"], "item_5_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1999-12-01", "bibliographicIssueDateType": "Issued"}, "bibliographic_titles": [{}, {"bibliographic_title": "Research Report NIFS-Series", "bibliographic_titleLang": "en"}]}]}, "item_5_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "\"A compact cesium deposition system was used for direct deposition of cesim atoms and ion onto the inner surface of the 1/3 scale Hydrogen Negative Ion Source for the LHD-NBI system. A small, well defined amount of cesium deposition in the range of 3-200 mg was tested. Negative ion extraction and acceleration were carried out both in the pure hydrogen operation mode and in the cesium mode. Single Cs deposition of 3-30 mg to the plasma chamber have produced temporary 2-5 times increases of H- yield, but the yield was decreased within several discharge pulses to the previous steady-state value. Two consecutive 30 mg depositions done within a 3-5 hours/ 60 shot interval, produced a similar temporary increase of H- beam, but reached a larger H-yielad steady-state value. Deposition of arger 0.1-0.2 g Cs portions with a 20-120 hours/150-270 shot interval improved the H-yield for a long (2-5 days) period of operation. Directed depositions of Cs to the various walls of the plasma chamber showed approximately the same H- increase. Deposition of 0.13 g Cs to a surface polluted by a water leak, produced a temporary increase, and an H- steady-state level similar to that from a single 30 mg cesium deposition. Deposition of 0.1 g with a cesium plasma produced one half the H-yield obtained by deposition of the same amount of cesium atoms. A higher steady-state H- current value and a smaller rate of H- yield decrease was recorded during the 8 filaments discharge operation, as compared to the 12 filaments operation at the same discharge power.\"", "subitem_description_type": "Abstract"}]}, "item_5_source_id_10": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0915-633X", "subitem_source_identifier_type": "ISSN"}]}, "item_5_text_25": {"attribute_name": "登録情報", "attribute_value_mlt": [{"subitem_text_value": "Made available in DSpace on 2010-02-05T10:18:34Z (GMT). No. of bitstreams: 0\n Previous issue date: 1999-12"}]}, "item_5_text_8": {"attribute_name": "報告書番号", "attribute_value_mlt": [{"subitem_text_value": "NIFS-620"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "\"Oka, Y.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "63082", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Takeiri, Y.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "63083", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yu.I., Belchenko", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "63084", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hamabe, M.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "63085", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kaneko, O.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "63086", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tsumori, K.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "63087", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Osakabe, M.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "63088", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Asano, E.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "63089", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kawamoto, T.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "63090", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Akiyama, R.\"", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "63091", "nameIdentifierScheme": "WEKO"}]}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "hydrogen negative ion", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "ion surce", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "cesium deposition", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "NBI", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "research report", "resourceuri": "http://purl.org/coar/resource_type/c_18ws"}]}, "item_title": "Optimization of Cs Deposition in the 1/3 Scale Hydrogen Negative Ion Source for LHD-NBI System", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Optimization of Cs Deposition in the 1/3 Scale Hydrogen Negative Ion Source for LHD-NBI System", "subitem_title_language": "en"}]}, "item_type_id": "5", "owner": "3", "path": ["32"], "permalink_uri": "http://hdl.handle.net/10655/2858", "pubdate": {"attribute_name": "公開日", "attribute_value": "2010-02-05"}, "publish_date": "2010-02-05", "publish_status": "0", "recid": "10110", "relation": {}, "relation_version_is_last": true, "title": ["Optimization of Cs Deposition in the 1/3 Scale Hydrogen Negative Ion Source for LHD-NBI System"], "weko_shared_id": -1}
Optimization of Cs Deposition in the 1/3 Scale Hydrogen Negative Ion Source for LHD-NBI System
http://hdl.handle.net/10655/2858
http://hdl.handle.net/10655/2858cda0af7c-2481-4516-86d9-deea1a0f789c
Item type | 研究報告書 / Research Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2010-02-05 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Optimization of Cs Deposition in the 1/3 Scale Hydrogen Negative Ion Source for LHD-NBI System | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | hydrogen negative ion | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | ion surce | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | cesium deposition | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | NBI | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_18ws | |||||
資源タイプ | research report | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
"Oka, Y.
× "Oka, Y.× Takeiri, Y.× Yu.I., Belchenko× Hamabe, M.× Kaneko, O.× Tsumori, K.× Osakabe, M.× Asano, E.× Kawamoto, T.× Akiyama, R." |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | "A compact cesium deposition system was used for direct deposition of cesim atoms and ion onto the inner surface of the 1/3 scale Hydrogen Negative Ion Source for the LHD-NBI system. A small, well defined amount of cesium deposition in the range of 3-200 mg was tested. Negative ion extraction and acceleration were carried out both in the pure hydrogen operation mode and in the cesium mode. Single Cs deposition of 3-30 mg to the plasma chamber have produced temporary 2-5 times increases of H- yield, but the yield was decreased within several discharge pulses to the previous steady-state value. Two consecutive 30 mg depositions done within a 3-5 hours/ 60 shot interval, produced a similar temporary increase of H- beam, but reached a larger H-yielad steady-state value. Deposition of arger 0.1-0.2 g Cs portions with a 20-120 hours/150-270 shot interval improved the H-yield for a long (2-5 days) period of operation. Directed depositions of Cs to the various walls of the plasma chamber showed approximately the same H- increase. Deposition of 0.13 g Cs to a surface polluted by a water leak, produced a temporary increase, and an H- steady-state level similar to that from a single 30 mg cesium deposition. Deposition of 0.1 g with a cesium plasma produced one half the H-yield obtained by deposition of the same amount of cesium atoms. A higher steady-state H- current value and a smaller rate of H- yield decrease was recorded during the 8 filaments discharge operation, as compared to the 12 filaments operation at the same discharge power." | |||||
書誌情報 |
en : Research Report NIFS-Series 発行日 1999-12-01 |
|||||
報告書番号 | ||||||
NIFS-620 | ||||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0915-633X |