Optimization of the Visible CXRS Measurements of TESPEL Diagnostics in LHD

http://hdl.handle.net/10655/3215
http://hdl.handle.net/10655/3215
30f0b42a-7aae-4fd8-bae7-301cafc204a1
Item type 研究報告書 / Research Paper(1)
公開日 2010-02-05
タイトル
タイトル Optimization of the Visible CXRS Measurements of TESPEL Diagnostics in LHD
言語 en
言語
言語 eng
キーワード
言語 en
主題Scheme Other
主題 diagnostics
キーワード
言語 en
主題Scheme Other
主題 impurity transport
キーワード
言語 en
主題Scheme Other
主題 pellet
キーワード
言語 en
主題Scheme Other
主題 charge exchange
キーワード
言語 en
主題Scheme Other
主題 radiation
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_18ws
資源タイプ research report
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 "Sergeev, V.Yu.

× "Sergeev, V.Yu.

en "Sergeev, V.Yu.

Search repository
Janev, R.K.

× Janev, R.K.

en Janev, R.K.

Search repository
Rakovic, M.J.

× Rakovic, M.J.

en Rakovic, M.J.

Search repository
ZOU, S.

× ZOU, S.

en ZOU, S.


Search repository
Tamura, N.

× Tamura, N.

en Tamura, N.

Search repository
KHLOPENKOV, K.V.

× KHLOPENKOV, K.V.

en KHLOPENKOV, K.V.


Search repository
Sudo, S."

× Sudo, S."

en Sudo, S."

Search repository
抄録
内容記述タイプ Abstract
内容記述 "A model for calculations of Charge eXchange Recombination (CXR) signals of impurity nuclei injected in high temperature plasma has been developed. For that purpose, the simplified collisional-radiative model for calculations of CXR signal and the corona equilibrium set of equations for ionization balance were solved taking into account the main physical processes involved. Scaling laws of partial CX cross sections with respect to both principal and angular quantum numbers of captured electron have been established on the basis of the results of Classical Trajectory Monte Carlo (CTMC) calculations. The CXR signals for a Li tracer in TESPEL experiments on LHD and CHS machines have been calculated. The difference of about two orders of magnitude in the calculated signals is due to the difference of both NBI neutral flux density and capture-radiation cross-sections and explains the lack of Li^3+ CXR signals in the measurements on LHD. Calculations of the CXR signals for various injected impurities have been performed for LHD conditions. The operational limits of the use of TESPEL diagnostics in the visible spectral range on LHD have been determined. For T_e=1-2 keV (P_NBI = 3 MW) and N_e=(2-5)cdot10^13 cm^-3, injection of F, Mg and Al as tracer materials is proposed."
書誌情報 en : Research Report NIFS-Series

発行日 2001-08-01
報告書番号
NIFS-710
ISSN
収録物識別子タイプ ISSN
収録物識別子 0915-633X
戻る
0
views
See details
Views

Versions

Ver.1 2023-06-20 20:52:27.527158
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3