{"_buckets": {"deposit": "31c8eaa5-2207-4976-ab6f-147d91a3564c"}, "_deposit": {"created_by": 21, "id": "11004", "owners": [21], "pid": {"revision_id": 0, "type": "depid", "value": "11004"}, "status": "published"}, "_oai": {"id": "oai:nifs-repository.repo.nii.ac.jp:00011004", "sets": ["7"]}, "author_link": ["122626", "66515"], "item_10001_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2021-04", "bibliographicIssueDateType": "Issued"}, "bibliographicPageStart": "103278", "bibliographicVolumeNumber": "115", "bibliographic_titles": [{"bibliographic_title": "Cryogenics"}]}]}, "item_10001_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The measurements of self-fields and voltages for the stacked tapes assembled in rigid structure (STARS) conductor were carried out when the conductor immersed in liquid nitrogen was energized. In the measurements, a 3 m straight line shaped STARS conductor, which is composed of 45 REBCO tapes (15 tapes × 3 rows) embedded in a copper stabilizer, was used as a conductor sample. The measurement results indicate that the ramp rate at the conductor excitation and the one-time thermal cycle of the conductor do not affect the self-fields but the voltages.\n\nThe current center position in the conductor cross-section during the conductor excitation was analyzed from the measurement results of the self-fields. The current center position always maintains the same position in the middle of the cross-section during the excitation. The analysis indicates that the current distribution of the STARS conductor is stable during the excitation. In addition, two-dimensional magnetic field calculations were conducted using the various models for the cross-sectional configuration of the STARS conductor. As a result, the calculation results agree with the measurement results regarding the self-fields.", "subitem_description_type": "Abstract"}]}, "item_10001_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": " \tELSEVIER "}]}, "item_10001_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1016/j.cryogenics.2021.103278", "subitem_relation_type_select": "DOI"}}]}, "item_10001_relation_16": {"attribute_name": "情報源", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "T. Obana, N. Yanagi, Measurements of self-field and voltage for the REBCO stacked tapes assembled in rigid structure (STARS) conductor at 77 K, Cryogenics, Volume 115, 2021, 103278, ISSN 0011-2275, https://doi.org/10.1016/j.cryogenics.2021.103278."}]}]}, "item_10001_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "Publisher version"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1016/j.cryogenics.2021.103278", "subitem_relation_type_select": "DOI"}}]}, "item_10001_rights_15": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "© 2021. This manuscript version is made available under the CC-BY-NC-ND 4.0 license https://doi.org/10.1016/j.cryogenics.2022.103419 "}]}, "item_10001_source_id_11": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AA00620634 ", "subitem_source_identifier_type": "NCID"}]}, "item_10001_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "00112275 ", "subitem_source_identifier_type": "ISSN"}]}, "item_10001_text_23": {"attribute_name": "NAIS", "attribute_value_mlt": [{"subitem_text_value": "|||"}]}, "item_10001_version_type_20": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_ab4af688f83e57aa", "subitem_version_type": "AM"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorAffiliations": [{"affiliationNameIdentifiers": [{"affiliationNameIdentifier": "", "affiliationNameIdentifierScheme": "ISNI", "affiliationNameIdentifierURI": "http://www.isni.org/isni/"}], "affiliationNames": [{"affiliationName": "", "affiliationNameLang": "ja"}]}], "creatorNames": [{"creatorName": "OBANA, Tetsuhiro", "creatorNameLang": "en"}], "familyNames": [{"familyName": "OBANA", "familyNameLang": "en"}], "givenNames": [{"givenName": " Tetsuhiro", "givenNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "122626", "nameIdentifierScheme": "WEKO"}]}, {"creatorAffiliations": [{"affiliationNameIdentifiers": [{"affiliationNameIdentifier": "", "affiliationNameIdentifierScheme": "ISNI", "affiliationNameIdentifierURI": "http://www.isni.org/isni/"}], "affiliationNames": [{"affiliationName": "", "affiliationNameLang": "ja"}]}], "creatorNames": [{"creatorName": "YANAGI, Nagato", "creatorNameLang": "en"}], "familyNames": [{"familyName": "YANAGI", "familyNameLang": "en"}], "givenNames": [{"givenName": " Nagato", "givenNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "66515", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2022-02-02"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "Cryogenics115_pp103278.pdf", "filesize": [{"value": "2.3 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_11", "mimetype": "application/pdf", "size": 2300000.0, "url": {"label": "Cryogenics115_pp103278", "url": "https://nifs-repository.repo.nii.ac.jp/record/11004/files/Cryogenics115_pp103278.pdf"}, "version_id": "23cd7b1a-14c9-4e85-99d7-45482a3195ab"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Magnetic field measurement", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Voltage measurement", "subitem_subject_scheme": "Other"}, {"subitem_subject": "REBCO tape", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Current distribution", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Magnetic field calculation", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Stacked tapes assembled in rigid structure (STARS) conductor", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Measurements of self-field and voltage for the REBCO stacked tapes assembled in rigid structure (STARS) conductor at 77 K", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Measurements of self-field and voltage for the REBCO stacked tapes assembled in rigid structure (STARS) conductor at 77 K"}]}, "item_type_id": "10001", "owner": "21", "path": ["7"], "permalink_uri": "http://hdl.handle.net/10655/00012964", "pubdate": {"attribute_name": "公開日", "attribute_value": "2022-02-02"}, "publish_date": "2022-02-02", "publish_status": "0", "recid": "11004", "relation": {}, "relation_version_is_last": true, "title": ["Measurements of self-field and voltage for the REBCO stacked tapes assembled in rigid structure (STARS) conductor at 77 K"], "weko_shared_id": -1}
Measurements of self-field and voltage for the REBCO stacked tapes assembled in rigid structure (STARS) conductor at 77 K
http://hdl.handle.net/10655/00012964
http://hdl.handle.net/10655/000129641f81276b-4434-4f0e-969e-e011d2d297d0
名前 / ファイル | ライセンス | アクション |
---|---|---|
Cryogenics115_pp103278 (2.3 MB)
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2022-02-02 | |||||
タイトル | ||||||
タイトル | Measurements of self-field and voltage for the REBCO stacked tapes assembled in rigid structure (STARS) conductor at 77 K | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Magnetic field measurement | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Voltage measurement | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | REBCO tape | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Current distribution | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Magnetic field calculation | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Stacked tapes assembled in rigid structure (STARS) conductor | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
OBANA, Tetsuhiro
× OBANA, Tetsuhiro× YANAGI, Nagato |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The measurements of self-fields and voltages for the stacked tapes assembled in rigid structure (STARS) conductor were carried out when the conductor immersed in liquid nitrogen was energized. In the measurements, a 3 m straight line shaped STARS conductor, which is composed of 45 REBCO tapes (15 tapes × 3 rows) embedded in a copper stabilizer, was used as a conductor sample. The measurement results indicate that the ramp rate at the conductor excitation and the one-time thermal cycle of the conductor do not affect the self-fields but the voltages. The current center position in the conductor cross-section during the conductor excitation was analyzed from the measurement results of the self-fields. The current center position always maintains the same position in the middle of the cross-section during the excitation. The analysis indicates that the current distribution of the STARS conductor is stable during the excitation. In addition, two-dimensional magnetic field calculations were conducted using the various models for the cross-sectional configuration of the STARS conductor. As a result, the calculation results agree with the measurement results regarding the self-fields. |
|||||
書誌情報 |
Cryogenics 巻 115, p. 103278, 発行日 2021-04 |
|||||
出版者 | ||||||
出版者 | ELSEVIER | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 00112275 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA00620634 | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.cryogenics.2021.103278 | |||||
権利 | ||||||
権利情報 | © 2021. This manuscript version is made available under the CC-BY-NC-ND 4.0 license https://doi.org/10.1016/j.cryogenics.2022.103419 | |||||
情報源 | ||||||
関連名称 | T. Obana, N. Yanagi, Measurements of self-field and voltage for the REBCO stacked tapes assembled in rigid structure (STARS) conductor at 77 K, Cryogenics, Volume 115, 2021, 103278, ISSN 0011-2275, https://doi.org/10.1016/j.cryogenics.2021.103278. | |||||
関連サイト | ||||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1016/j.cryogenics.2021.103278 | |||||
関連名称 | Publisher version | |||||
著者版フラグ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa | |||||