Evaluation AC Losses in Large-Scale Conductors Consisting of Stacked REBCO Tapes

http://hdl.handle.net/10655/00013015
http://hdl.handle.net/10655/00013015
c86a345d-c565-414b-92f1-8a4d9c3ea5bc
名前 / ファイル ライセンス アクション
pfr2021_16-2405071.pdf pfr2021_16-2405071 (498.7 kB)
license.icon
Item type 学術雑誌論文 / Journal Article(1)
公開日 2022-02-14
タイトル
タイトル Evaluation AC Losses in Large-Scale Conductors Consisting of Stacked REBCO Tapes
言語
言語 eng
キーワード
主題Scheme Other
主題 hysteresis loss
キーワード
主題Scheme Other
主題 coupling loss
キーワード
主題Scheme Other
主題 REBCO
キーワード
主題Scheme Other
主題 conductor
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 UENO, Yuma

× UENO, Yuma

UENO, Yuma

Search repository
NAGAMOTO, Naohiro

× NAGAMOTO, Naohiro

NAGAMOTO, Naohiro

Search repository
KAWAGOE, Akifumi

× KAWAGOE, Akifumi

KAWAGOE, Akifumi

Search repository
OBANA, Tetsuhiro

× OBANA, Tetsuhiro

OBANA, Tetsuhiro

Search repository
TAKAYASU, Makoto

× TAKAYASU, Makoto

TAKAYASU, Makoto

Search repository
著者ID
内容記述タイプ Other
内容記述 0000-0003-3100-6328
抄録
内容記述タイプ Abstract
内容記述 In this work, stacked model conductors consisting of dozens of YBCO tapes were fabricated and experimentally investigated to determine whether the hysteresis and coupling losses affect each other. When an oblique magnetic field is applied to the tape, hysteresis and coupling losses are expected to be generated simultaneously. A uniform AC transverse magnetic field was applied to the sample in liquid nitrogen, and the AC losses were measured via the pickup coil method. The measurements were carried with the magnetic field applied at various angles with respect to the tape wide surface. The measured AC losses were separated into hysteresis and coupling losses. The measured hysteresis losses well agreed with the theoretical values for a square cross-section superconductor. This indicates that hysteresis losses can be considered in terms of the magnetic field component perpendicular to the flat face of the YBCO tape. The coupling time constant was found to be independent of the applied magnetic field angle. This shows that coupling losses can be considered in terms of the magnetic field component parallel to the tape's wide surface, and the permeability in the conductor can be assumed to be the vacuum permeability.
書誌情報 Plasma and Fusion Research

巻 16, 号 Special Issue 1, p. 2405071, 発行日 2021-06-23
書誌的事項
the 29th International Toki Conference on Plasma and Fusion Research (ITC29)
出版者
出版者 The Japan Society of Plasma Science and Nuclear Fusion Research
ISSN
収録物識別子タイプ ISSN
収録物識別子 1880-6821
書誌レコードID
収録物識別子タイプ NCID
収録物識別子 AA12346675
DOI
関連タイプ isIdenticalTo
識別子タイプ DOI
関連識別子 10.1585/pfr.16.2405071
権利
権利情報 (c) 2021 The Japan Society of Plasma Science and Nuclear Fusion Research
関連サイト
識別子タイプ DOI
関連識別子 https://doi.org/10.1585/pfr.16.2405071
関連名称 Publisher version
著者版フラグ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
NAIS
|||
戻る
0
views
See details
Views

Versions

Ver.1 2023-06-20 16:30:32.679404
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3