{"_buckets": {"deposit": "13fb7ef8-a856-4028-a537-802e19193ee5"}, "_deposit": {"created_by": 3, "id": "349", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "349"}, "status": "published"}, "_oai": {"id": "oai:nifs-repository.repo.nii.ac.jp:00000349", "sets": ["7"]}, "author_link": ["123165", "123167", "123168", "123157", "123161", "123164", "123166", "123163", "123160", "123159", "123158", "123162"], "item_2_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2012-02-01", "bibliographicIssueDateType": "Issued"}, "bibliographicPageStart": "2405007-1 - 2405007-4", "bibliographicVolumeNumber": "Vol. 7", "bibliographic_titles": [{}, {"bibliographic_title": "Plasma and Fusion Research", "bibliographic_titleLang": "en"}]}]}, "item_2_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "To deal with endless data streams acquired in LHD steady-state experiments, the LHD data acquisition system was designed with a simple concept that divides a long pulse into a consecutive series of 10-s “subshots”. Latest digitizers applying high-speed PCI-Express technology, however, output nonstop gigabyte per second data streams whose subshot intervals would be extremely long if 10-s rule was applied. These digitizers need shorter subshot intervals, less than 10-s long. In contrast, steady-state fusion plants need uninterrupted monitoring of the environment and device soundness. They adopt longer subshot lengths of either 10 min or 1 day. To cope with both uninterrupted monitoring and ultra-fast diagnostics, the ability to vary the subshot length according to the type of operation is required. In this study, a design modification that enables variable subshot lengths was implemented and its practical effectiveness in LHD was verified.", "subitem_description_type": "Abstract"}]}, "item_2_description_6": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "? 2012 The Japan Society of Plasma Science and Nuclear Fusion Research", "subitem_description_type": "Other"}]}, "item_2_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "プラズマ・核融合学会"}]}, "item_2_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1585/pfr.7.2405007", "subitem_relation_type_select": "DOI"}}]}, "item_2_text_24": {"attribute_name": "登録情報", "attribute_value_mlt": [{"subitem_text_value": "Submitted by Kanae Hashimoto (kanae@nifs.ac.jp) on 2012-07-23T04:40:47Z\nNo. of bitstreams: 1\npfr2012_07-2405007.pdf: 2602995 bytes, checksum: a2e243c7b102a63ab5e8192086824f77 (MD5)@@@Made available in DSpace on 2012-07-23T04:41:06Z (GMT). No. of bitstreams: 1\npfr2012_07-2405007.pdf: 2602995 bytes, checksum: a2e243c7b102a63ab5e8192086824f77 (MD5)\n Previous issue date: 2012-02"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "NAKANISHI, Hideya", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "123157", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "IMAZU, Setsuo", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "123158", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "OHSUNA, Masaki", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "123159", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "KOJIMA, Mamoru", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "123160", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "NONOMURA, Miki", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "123161", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "SHOJI, Mamoru", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "123162", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "EMOTO, Masahiko", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "123163", "nameIdentifierScheme": "WEKO"}]}, {"creatorAffiliations": [{"affiliationNameIdentifiers": [{"affiliationNameIdentifier": "", "affiliationNameIdentifierScheme": "ISNI", "affiliationNameIdentifierURI": "http://www.isni.org/isni/"}], "affiliationNames": [{"affiliationName": "", "affiliationNameLang": "ja"}]}], "creatorNames": [{"creatorName": "YOSHIDA, Masanobu", "creatorNameLang": "en"}], "familyNames": [{"familyName": "YOSHIDA", "familyNameLang": "en"}], "givenNames": [{"givenName": " Masanobu", "givenNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "123164", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "IWATA, Chie", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "123165", "nameIdentifierScheme": "WEKO"}]}, {"creatorAffiliations": [{"affiliationNameIdentifiers": [{"affiliationNameIdentifier": "", "affiliationNameIdentifierScheme": "ISNI", "affiliationNameIdentifierURI": "http://www.isni.org/isni/"}], "affiliationNames": [{"affiliationName": "", "affiliationNameLang": "ja"}]}], "creatorNames": [{"creatorName": "MIYAKE, Hitoshi", "creatorNameLang": "en"}], "familyNames": [{"familyName": "MIYAKE", "familyNameLang": "en"}], "givenNames": [{"givenName": " Hitoshi", "givenNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "123166", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "NAGAYAMA, Yoshio", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "123167", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "KAWAHATA, Kazuo", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "123168", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2016-03-23"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "pfr2012_07-2405007.pdf", "filesize": [{"value": "2.6 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 2600000.0, "url": {"label": "pfr2012_07-2405007.pdf", "url": "https://nifs-repository.repo.nii.ac.jp/record/349/files/pfr2012_07-2405007.pdf"}, "version_id": "52a972aa-d497-438d-af62-18ae17bf11cf"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "real-time data acquisition (RT-DAQ)", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "variable subshot", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "environmental radiation monitoring", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "device soundness", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "LABCOM system", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Improved Data Acquisition Methods for Uninterrupted Signal Monitoring and Ultra-Fast Plasma Diagnostics in LHD", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Improved Data Acquisition Methods for Uninterrupted Signal Monitoring and Ultra-Fast Plasma Diagnostics in LHD", "subitem_title_language": "en"}]}, "item_type_id": "2", "owner": "3", "path": ["7"], "permalink_uri": "http://hdl.handle.net/10655/8925", "pubdate": {"attribute_name": "公開日", "attribute_value": "2012-07-23"}, "publish_date": "2012-07-23", "publish_status": "0", "recid": "349", "relation": {}, "relation_version_is_last": true, "title": ["Improved Data Acquisition Methods for Uninterrupted Signal Monitoring and Ultra-Fast Plasma Diagnostics in LHD"], "weko_shared_id": -1}
Improved Data Acquisition Methods for Uninterrupted Signal Monitoring and Ultra-Fast Plasma Diagnostics in LHD
http://hdl.handle.net/10655/8925
http://hdl.handle.net/10655/8925973d5940-ad37-466f-8554-6288289b7cf9
名前 / ファイル | ライセンス | アクション |
---|---|---|
pfr2012_07-2405007.pdf (2.6 MB)
|
|
Item type | 学術雑誌論文 / Journal Article_02(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2012-07-23 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Improved Data Acquisition Methods for Uninterrupted Signal Monitoring and Ultra-Fast Plasma Diagnostics in LHD | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | real-time data acquisition (RT-DAQ) | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | variable subshot | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | environmental radiation monitoring | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | device soundness | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | LABCOM system | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
NAKANISHI, Hideya
× NAKANISHI, Hideya× IMAZU, Setsuo× OHSUNA, Masaki× KOJIMA, Mamoru× NONOMURA, Miki× SHOJI, Mamoru× EMOTO, Masahiko× YOSHIDA, Masanobu× IWATA, Chie× MIYAKE, Hitoshi× NAGAYAMA, Yoshio× KAWAHATA, Kazuo |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | To deal with endless data streams acquired in LHD steady-state experiments, the LHD data acquisition system was designed with a simple concept that divides a long pulse into a consecutive series of 10-s “subshots”. Latest digitizers applying high-speed PCI-Express technology, however, output nonstop gigabyte per second data streams whose subshot intervals would be extremely long if 10-s rule was applied. These digitizers need shorter subshot intervals, less than 10-s long. In contrast, steady-state fusion plants need uninterrupted monitoring of the environment and device soundness. They adopt longer subshot lengths of either 10 min or 1 day. To cope with both uninterrupted monitoring and ultra-fast diagnostics, the ability to vary the subshot length according to the type of operation is required. In this study, a design modification that enables variable subshot lengths was implemented and its practical effectiveness in LHD was verified. | |||||
内容記述 | ||||||
内容記述タイプ | Other | |||||
内容記述 | ? 2012 The Japan Society of Plasma Science and Nuclear Fusion Research | |||||
書誌情報 |
en : Plasma and Fusion Research 巻 Vol. 7, p. 2405007-1 - 2405007-4, 発行日 2012-02-01 |
|||||
出版者 | ||||||
出版者 | プラズマ・核融合学会 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1585/pfr.7.2405007 |