WEKO3
アイテム
{"_buckets": {"deposit": "a7d29052-1122-40a3-9f66-a31c1d47265f"}, "_deposit": {"created_by": 3, "id": "412", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "412"}, "status": "published"}, "_oai": {"id": "oai:nifs-repository.repo.nii.ac.jp:00000412", "sets": ["7"]}, "author_link": ["123844", "123839", "123846", "123840", "123843", "123845", "123841", "123842"], "item_2_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2012-10-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "Issue10", "bibliographicPageStart": "10E322-1 - 10E322-3", "bibliographicVolumeNumber": "Vol.83", "bibliographic_titles": [{}, {"bibliographic_title": "Review of Scientific Instruments", "bibliographic_titleLang": "en"}]}]}, "item_2_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "In order to measure the poloidal rotation velocity, a Doppler reflectometer has been developed in Large Helical Device (LHD). A remotely controlled antenna tilting system has been installed in an LHD vacuum vessel. A synthesizer is used as the source, and the operation microwave frequency ranges are ka-band and V-band. In LHD last experimental campaign we obtained the Doppler shifted signal, which was consistent with CXRS measurements.", "subitem_description_type": "Abstract"}]}, "item_2_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "American Institute of Physics"}]}, "item_2_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1063/1.4733736", "subitem_relation_type_select": "DOI"}}]}, "item_2_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "Publisher version"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1063/1.4733736", "subitem_relation_type_select": "DOI"}}]}, "item_2_rights_15": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "(c) 2012 American Institute of Physics"}]}, "item_2_text_24": {"attribute_name": "登録情報", "attribute_value_mlt": [{"subitem_text_value": "Submitted by Kanae Hashimoto (kanae@nifs.ac.jp) on 2013-02-25T01:10:44ZNo. of bitstreams: 1RevSciInstrum_83_10E322.pdf: 1734668 bytes, checksum: ec791de190a24274e82145782024e24c (MD5)@@@Made available in DSpace on 2013-02-25T01:10:56Z (GMT). No. of bitstreams: 1RevSciInstrum_83_10E322.pdf: 1734668 bytes, checksum: ec791de190a24274e82145782024e24c (MD5) Previous issue date: 2012-10"}]}, "item_2_version_type_20": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Tokuzawa, T.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "123839", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ejiri, A.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "123840", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kawahata, K.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "123841", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tanaka, K.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "123842", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamada, I.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "123843", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yoshinuma, M.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "123844", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ida, K.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "123845", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Suzuki, C.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "123846", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2016-03-23"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "RevSciInstrum_83_10E322.pdf", "filesize": [{"value": "1.7 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_11", "mimetype": "application/pdf", "size": 1700000.0, "url": {"label": "RevSciInstrum_83_10E322.pdf", "url": "https://nifs-repository.repo.nii.ac.jp/record/412/files/RevSciInstrum_83_10E322.pdf"}, "version_id": "287be433-1ef4-4bdf-b152-bd4977bfe4af"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Microwave Doppler reflectometer system in LHD", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Microwave Doppler reflectometer system in LHD"}]}, "item_type_id": "2", "owner": "3", "path": ["7"], "permalink_uri": "http://hdl.handle.net/10655/10138", "pubdate": {"attribute_name": "公開日", "attribute_value": "2013-02-25"}, "publish_date": "2013-02-25", "publish_status": "0", "recid": "412", "relation": {}, "relation_version_is_last": true, "title": ["Microwave Doppler reflectometer system in LHD"], "weko_shared_id": 3}
Microwave Doppler reflectometer system in LHD
http://hdl.handle.net/10655/10138
http://hdl.handle.net/10655/101380dfd4cfa-a902-497c-9fad-5736b6f7e3db
名前 / ファイル | ライセンス | アクション |
---|---|---|
RevSciInstrum_83_10E322.pdf (1.7 MB)
|
Item type | 学術雑誌論文 / Journal Article_02(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2013-02-25 | |||||
タイトル | ||||||
タイトル | Microwave Doppler reflectometer system in LHD | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Tokuzawa, T.
× Tokuzawa, T.× Ejiri, A.× Kawahata, K.× Tanaka, K.× Yamada, I.× Yoshinuma, M.× Ida, K.× Suzuki, C. |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | In order to measure the poloidal rotation velocity, a Doppler reflectometer has been developed in Large Helical Device (LHD). A remotely controlled antenna tilting system has been installed in an LHD vacuum vessel. A synthesizer is used as the source, and the operation microwave frequency ranges are ka-band and V-band. In LHD last experimental campaign we obtained the Doppler shifted signal, which was consistent with CXRS measurements. | |||||
書誌情報 |
en : Review of Scientific Instruments 巻 Vol.83, 号 Issue10, p. 10E322-1 - 10E322-3, 発行日 2012-10-01 |
|||||
出版者 | ||||||
出版者 | American Institute of Physics | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1063/1.4733736 | |||||
権利 | ||||||
権利情報 | (c) 2012 American Institute of Physics | |||||
関連サイト | ||||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1063/1.4733736 | |||||
関連名称 | Publisher version | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |