WEKO3
アイテム
{"_buckets": {"deposit": "fd457f72-9644-4c7f-99b3-5d1ef00f88c3"}, "_deposit": {"created_by": 3, "id": "653", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "653"}, "status": "published"}, "_oai": {"id": "oai:nifs-repository.repo.nii.ac.jp:00000653", "sets": ["7"]}, "author_link": ["126034", "126040", "126038", "126035", "126039", "126036", "126037", "126033"], "item_2_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2004-10-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "Issue10", "bibliographicPageStart": "pp.3604-3606", "bibliographicVolumeNumber": "Vol.75", "bibliographic_titles": [{}, {"bibliographic_title": "Review of Scientific Instruments", "bibliographic_titleLang": "en"}]}]}, "item_2_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A high-energy neutral particle measurement is one of the important diagnostics for ion temperature and high-energy particle confinement analysis. The neutral particle analyzer in the large helical device is capable of wide range scanning as a feature. We have obtained various data using the horizontal scan of the analyzer. Recently, in addition to the horizontal scan, a high-speed perpendicular scan became possible which enables acquisition of new information in the poloidal direction. Two stainless blocks are set on the opposite sides of the chain in order to balance the weight (700 kg) of the analyzer and reduce the load for the motor. Therefore a very high scan speed of 1°/s can be obtained. The scanning speed is 1°/s. By adding the vertical scan, the ion temperature profile and the radial variation of the signal loss associated with the resonant loss was obtained in preliminary experimental results.", "subitem_description_type": "Abstract"}]}, "item_2_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "American Institute of Physics"}]}, "item_2_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1063/1.1788856", "subitem_relation_type_select": "DOI"}}]}, "item_2_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "Publisher version"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1063/1.1788856", "subitem_relation_type_select": "DOI"}}]}, "item_2_rights_15": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "? 2004 American Institute of Physics."}]}, "item_2_text_24": {"attribute_name": "登録情報", "attribute_value_mlt": [{"subitem_text_value": "Submitted by Kanae Hashimoto (kanae@nifs.ac.jp) on 2010-02-09T02:43:20ZNo. of bitstreams: 1431.pdf: 205743 bytes, checksum: 2888b5f80cf486fdce9c4dd082989ec3 (MD5)@@@Made available in DSpace on 2010-02-09T02:43:30Z (GMT). No. of bitstreams: 1431.pdf: 205743 bytes, checksum: 2888b5f80cf486fdce9c4dd082989ec3 (MD5) Previous issue date: 2004-10"}]}, "item_2_version_type_20": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Ozaki, T.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "126033", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Goncharov, P.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "126034", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sudo, S.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "126035", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shoji, M.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "126036", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kawahata, K.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "126037", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kaneko, O.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "126038", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "the, LHD Experimental Group", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "126039", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Murakami, S.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "126040", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2016-03-23"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "431.pdf", "filesize": [{"value": "205.7 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_11", "mimetype": "application/pdf", "size": 205700.0, "url": {"label": "431.pdf", "url": "https://nifs-repository.repo.nii.ac.jp/record/653/files/431.pdf"}, "version_id": "73382fde-6104-47fe-b9ab-115474201d21"}, {"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2022-03-17"}], "displaytype": "detail", "download_preview_message": "", "file_order": 1, "filename": "VoR_Rev.Sci.Instr75-3604.pdf", "filesize": [{"value": "744.9 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_11", "mimetype": "application/pdf", "size": 744900.0, "url": {"label": "VoR_Rev.Sci.Instr75-3604", "url": "https://nifs-repository.repo.nii.ac.jp/record/653/files/VoR_Rev.Sci.Instr75-3604.pdf"}, "version_id": "804acb50-fd68-456c-b683-2041d4973097"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Two-dimensional scanning high-energy particle diagnostic system in Large Helical Device", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Two-dimensional scanning high-energy particle diagnostic system in Large Helical Device"}]}, "item_type_id": "2", "owner": "3", "path": ["7"], "permalink_uri": "http://hdl.handle.net/10655/3260", "pubdate": {"attribute_name": "公開日", "attribute_value": "2010-02-09"}, "publish_date": "2010-02-09", "publish_status": "0", "recid": "653", "relation": {}, "relation_version_is_last": true, "title": ["Two-dimensional scanning high-energy particle diagnostic system in Large Helical Device"], "weko_shared_id": 3}
Two-dimensional scanning high-energy particle diagnostic system in Large Helical Device
http://hdl.handle.net/10655/3260
http://hdl.handle.net/10655/326096bd0f56-9fe6-434a-8636-be803bfba1d0
名前 / ファイル | ライセンス | アクション |
---|---|---|
431.pdf (205.7 kB)
|
||
VoR_Rev.Sci.Instr75-3604 (744.9 kB)
|
Item type | 学術雑誌論文 / Journal Article_02(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2010-02-09 | |||||
タイトル | ||||||
タイトル | Two-dimensional scanning high-energy particle diagnostic system in Large Helical Device | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Ozaki, T.
× Ozaki, T.× Goncharov, P.× Sudo, S.× Shoji, M.× Kawahata, K.× Kaneko, O.× the, LHD Experimental Group× Murakami, S. |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A high-energy neutral particle measurement is one of the important diagnostics for ion temperature and high-energy particle confinement analysis. The neutral particle analyzer in the large helical device is capable of wide range scanning as a feature. We have obtained various data using the horizontal scan of the analyzer. Recently, in addition to the horizontal scan, a high-speed perpendicular scan became possible which enables acquisition of new information in the poloidal direction. Two stainless blocks are set on the opposite sides of the chain in order to balance the weight (700 kg) of the analyzer and reduce the load for the motor. Therefore a very high scan speed of 1°/s can be obtained. The scanning speed is 1°/s. By adding the vertical scan, the ion temperature profile and the radial variation of the signal loss associated with the resonant loss was obtained in preliminary experimental results. | |||||
書誌情報 |
en : Review of Scientific Instruments 巻 Vol.75, 号 Issue10, p. pp.3604-3606, 発行日 2004-10-01 |
|||||
出版者 | ||||||
出版者 | American Institute of Physics | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1063/1.1788856 | |||||
権利 | ||||||
権利情報 | ? 2004 American Institute of Physics. | |||||
関連サイト | ||||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1063/1.1788856 | |||||
関連名称 | Publisher version | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |