WEKO3
アイテム
{"_buckets": {"deposit": "564fb172-e900-4e4e-9acf-ebd5287ae5e7"}, "_deposit": {"created_by": 3, "id": "9686", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "9686"}, "status": "published"}, "_oai": {"id": "oai:nifs-repository.repo.nii.ac.jp:00009686", "sets": ["32"]}, "author_link": ["68929", "68930", "68931", "68927", "68928"], "item_5_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1996-02-01", "bibliographicIssueDateType": "Issued"}, "bibliographic_titles": [{}, {"bibliographic_title": "Research Report NIFS-Series", "bibliographic_titleLang": "en"}]}]}, "item_5_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A new charge exchange spectroscopic technique using a Fabry-Perot spectrometer has been developed to increase the photon flux at the detector and improve the time resolution of ion temperature and plasma rotation velocity measurements. The spectral resolution is obtained by arranging two dimensional fiber optics and a two dimensional detector at the focal plane of a coupled lens located on both sides of a Fabry-Perot spectrometer. The effective finesse of the Fabry-Perot interferometer in this system is 14. The time evolution of the ion temperature is obtained with a time resolution of 125 mu s and with the spatial resolution of 3 cm (8channels).", "subitem_description_type": "Abstract"}]}, "item_5_source_id_10": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0915-633X", "subitem_source_identifier_type": "ISSN"}]}, "item_5_text_25": {"attribute_name": "登録情報", "attribute_value_mlt": [{"subitem_text_value": "Made available in DSpace on 2010-02-05T10:17:22Z (GMT). No. of bitstreams: 1\nNIFS-401.pdf: 428963 bytes, checksum: 4724f84b0449028f804f675f2d027eb6 (MD5)\n Previous issue date: 1996-02"}]}, "item_5_text_8": {"attribute_name": "報告書番号", "attribute_value_mlt": [{"subitem_text_value": "NIFS-401"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Ida, K.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "68927", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Xu, J", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "68928", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sato, K.N.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "68929", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sakakita, H.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "68930", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "JIPP, TII-U group", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "68931", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2016-03-11"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "NIFS-401.pdf", "filesize": [{"value": "429.0 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 429000.0, "url": {"label": "NIFS-401.pdf", "url": "https://nifs-repository.repo.nii.ac.jp/record/9686/files/NIFS-401.pdf"}, "version_id": "ac9cf3dc-77b4-4cfa-bfbb-f46dcbeadddc"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Charge-exchange spectroscopy", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "ion temperature", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "pellet injection", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "research report", "resourceuri": "http://purl.org/coar/resource_type/c_18ws"}]}, "item_title": "Fast Charge Exchange Spectroscopy Using a Fabry-Perot Spectrometer in the JIPP TII-U Tokamak", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Fast Charge Exchange Spectroscopy Using a Fabry-Perot Spectrometer in the JIPP TII-U Tokamak", "subitem_title_language": "en"}]}, "item_type_id": "5", "owner": "3", "path": ["32"], "permalink_uri": "http://hdl.handle.net/10655/2617", "pubdate": {"attribute_name": "公開日", "attribute_value": "2010-02-05"}, "publish_date": "2010-02-05", "publish_status": "0", "recid": "9686", "relation": {}, "relation_version_is_last": true, "title": ["Fast Charge Exchange Spectroscopy Using a Fabry-Perot Spectrometer in the JIPP TII-U Tokamak"], "weko_shared_id": -1}
Fast Charge Exchange Spectroscopy Using a Fabry-Perot Spectrometer in the JIPP TII-U Tokamak
http://hdl.handle.net/10655/2617
http://hdl.handle.net/10655/2617db18bd95-9268-4ecb-a9a0-9cee26e63e4e
名前 / ファイル | ライセンス | アクション |
---|---|---|
NIFS-401.pdf (429.0 kB)
|
|
Item type | 研究報告書 / Research Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2010-02-05 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Fast Charge Exchange Spectroscopy Using a Fabry-Perot Spectrometer in the JIPP TII-U Tokamak | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Charge-exchange spectroscopy | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | ion temperature | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | pellet injection | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_18ws | |||||
資源タイプ | research report | |||||
著者 |
Ida, K.
× Ida, K.× Xu, J× Sato, K.N.× Sakakita, H.× JIPP, TII-U group |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A new charge exchange spectroscopic technique using a Fabry-Perot spectrometer has been developed to increase the photon flux at the detector and improve the time resolution of ion temperature and plasma rotation velocity measurements. The spectral resolution is obtained by arranging two dimensional fiber optics and a two dimensional detector at the focal plane of a coupled lens located on both sides of a Fabry-Perot spectrometer. The effective finesse of the Fabry-Perot interferometer in this system is 14. The time evolution of the ion temperature is obtained with a time resolution of 125 mu s and with the spatial resolution of 3 cm (8channels). | |||||
書誌情報 |
en : Research Report NIFS-Series 発行日 1996-02-01 |
|||||
報告書番号 | ||||||
NIFS-401 | ||||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0915-633X |