{"created":"2023-06-20T15:07:53.313969+00:00","id":104,"links":{},"metadata":{"_buckets":{"deposit":"f9ff6598-2a3c-416a-8e05-6090c7c7e846"},"_deposit":{"created_by":3,"id":"104","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"104"},"status":"published"},"_oai":{"id":"oai:nifs-repository.repo.nii.ac.jp:00000104","sets":["6:7"]},"author_link":["66593","66588","66591","66589","66587","66592","66590"],"item_2_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2007-01-01","bibliographicIssueDateType":"Issued"},"bibliographicPageStart":"S1027-1-S1027-4","bibliographicVolumeNumber":"Vol.2","bibliographic_titles":[{},{"bibliographic_title":"Plasma and Fusion Research","bibliographic_titleLang":"en"}]}]},"item_2_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"This paper describes innovative laser diagnostics under development at the National Institute for Fusion Science, aiming for the establishment of reliable density measurement techniques in the next step magnetically\nconfined fusion devices. There are two approaches, interferometry and polarimetry. A new type of two color laser (47.6/57.2-μm CH3OD) interferometer has been developed and its original function, vibration subtraction,\nwas confirmed in a test stand. The line integrated density measurement at Compact Helical System by using the polarimeter based on Cotton-Mouton effect was demonstrated by the use of a 337-μm HCN laser source.","subitem_description_type":"Abstract"}]},"item_2_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"プラズマ・核融合学会"}]},"item_2_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1585/pfr.2.S1027","subitem_relation_type_select":"DOI"}}]},"item_2_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"? 2007 The Japan Society of Plasma Science and Nuclear Fusion Research"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"KAWAHATA, Kazuo","creatorNameLang":"en"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"AKIYAMA, Tsuyoshi","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"PAVLICHENKO, Rostislav","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"ITO, Yasuhiko","creatorNameLang":"en"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"NAKAYAMA, Kazuya","creatorNameLang":"en"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"OKAJIMA, Shigeki","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"TSUJI-IIO, Shunji","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2016-03-11"}],"displaytype":"detail","filename":"pfr2007_02-S1027.pdf","filesize":[{"value":"363.5 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"pfr2007_02-S1027.pdf","url":"https://nifs-repository.repo.nii.ac.jp/record/104/files/pfr2007_02-S1027.pdf"},"version_id":"35f895ad-bd14-46fe-abc0-d2e197222fc1"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"plasma diagnostic","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"far-infrared laser","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"interferometry","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"two color","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Cotton-Mouton effect","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Advanced Laser Diagnostics for Electron Density Measurements","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Advanced Laser Diagnostics for Electron Density Measurements","subitem_title_language":"en"}]},"item_type_id":"2","owner":"3","path":["7"],"pubdate":{"attribute_name":"公開日","attribute_value":"2011-03-22"},"publish_date":"2011-03-22","publish_status":"0","recid":"104","relation_version_is_last":true,"title":["Advanced Laser Diagnostics for Electron Density Measurements"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-08-22T05:54:22.960447+00:00"}