{"created":"2023-06-20T15:16:49.027612+00:00","id":10544,"links":{},"metadata":{"_buckets":{"deposit":"73028ec5-fb9e-4dad-9add-4afcf442531a"},"_deposit":{"created_by":19,"id":"10544","owners":[19],"pid":{"revision_id":0,"type":"depid","value":"10544"},"status":"published"},"_oai":{"id":"oai:nifs-repository.repo.nii.ac.jp:00010544","sets":["6:7"]},"author_link":["126260","126258","126261","126257","66732","126259","66274","126256"],"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2016-09-08","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"12","bibliographicPageStart":"126006","bibliographicVolumeNumber":"56","bibliographic_titles":[{"bibliographic_title":"NUclear Fusion"}]}]},"item_10001_description_4":{"attribute_name":"著者ID","attribute_value_mlt":[{"subitem_description":"0000-0001-6090-5010","subitem_description_type":"Other"}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"We have investigated plasma detachment phenomena of high-density helium plasmas in the linear plasma device Pilot-PSI, which can realize a relevant ITER SOL/Divertor plasma condition. The experiment clearly indicated plasma detachment features such as drops in the plasma pressure and particle flux along the magnetic field lines that were observed under the condition of high neutral pressure; a feature of flux drop was parameterized using the degree of detachment (DOD) index. Fundamental plasma parameters such as electron temperature (Te) and electron density in the detached recombining plasmas were measured by different methods: reciprocating electrostatic probes, Thomson scattering (TS), and optical emission spectroscopy (OES). The Te measured using single and double probes corresponded to the TS measurement. No anomalies in the single probe I–V characteristics, observed in other linear plasma devices [16, 17, 36], appeared under the present condition in the Pilot-PSI device. A possible reason for this difference is discussed by comparing the different linear devices. The OES results are also compared with the simulation results of a collisional radiative (CR) model. Further, we demonstrated more than 90% of parallel particle and heat fluxes were dissipated in a short length of 0.5 m under the high neutral pressure condition in Pilot-PSI.","subitem_description_type":"Abstract"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"IOP Publishing"}]},"item_10001_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1088/0029-5515/56/12/126006","subitem_relation_type_select":"DOI"}}]},"item_10001_relation_16":{"attribute_name":"情報源","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"Y. Hayashi et al 2016 Nucl. Fusion 56 126006"}]}]},"item_10001_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"Publisher version"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1088/0029-5515/56/12/126006","subitem_relation_type_select":"DOI"}}]},"item_10001_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"This is the Accepted Manuscript version of an article accepted for publication in Nuclear Fusion. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The Version of Record is available online at https://doi.org/10.1088/0029-5515/56/12/126006."}]},"item_10001_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA12472385 ","subitem_source_identifier_type":"NCID"}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0029-5515","subitem_source_identifier_type":"ISSN"}]},"item_10001_text_23":{"attribute_name":"NAIS","attribute_value_mlt":[{"subitem_text_value":"|||"}]},"item_10001_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Hayashi, Yuki"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Ješko, K."}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Meiden, H.J. van der"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Vernimmen, J.W.M."}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Morgan, T.W."}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"OHNO, Noriyasu"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Yoshikawa, M."}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"MASUZAKI, Suguru"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2021-06-30"}],"displaytype":"detail","filename":"Nucl.Fusion56(12)_pp126006.pdf","filesize":[{"value":"2.5 MB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"Nucl.Fusion56(12)_pp126006","url":"https://nifs-repository.repo.nii.ac.jp/record/10544/files/Nucl.Fusion56(12)_pp126006.pdf"},"version_id":"00e68198-d9d4-47e1-93ce-9086a7194e51"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"plasma detachment","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"electrostatic probe measurement","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"electron-ion recombination","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"heat flux","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"divertor","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Pilot-PSI","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Plasma detachment study of high density helium plasmas in the Pilot-PSI device","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Plasma detachment study of high density helium plasmas in the Pilot-PSI device"}]},"item_type_id":"10001","owner":"19","path":["7"],"pubdate":{"attribute_name":"公開日","attribute_value":"2021-06-30"},"publish_date":"2021-06-30","publish_status":"0","recid":"10544","relation_version_is_last":true,"title":["Plasma detachment study of high density helium plasmas in the Pilot-PSI device"],"weko_creator_id":"19","weko_shared_id":19},"updated":"2023-09-26T02:46:41.782191+00:00"}