{"created":"2023-06-20T15:16:49.126067+00:00","id":10548,"links":{},"metadata":{"_buckets":{"deposit":"ab6303cf-3be6-47f2-b73e-372b191549e7"},"_deposit":{"created_by":19,"id":"10548","owners":[19],"pid":{"revision_id":0,"type":"depid","value":"10548"},"status":"published"},"_oai":{"id":"oai:nifs-repository.repo.nii.ac.jp:00010548","sets":["6:7"]},"author_link":["66768","126256","66765","66732"],"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2017-06-16","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"6","bibliographicPageStart":"062509","bibliographicVolumeNumber":"24","bibliographic_titles":[{"bibliographic_title":"Physics of Plasmas"}]}]},"item_10001_description_4":{"attribute_name":"著者ID","attribute_value_mlt":[{"subitem_description":"0000-0001-6090-5010","subitem_description_type":"Other"}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"We investigated the effects of magnetic field structure on detached plasma formation by simulating magnetically expanding and contracting plasma in a linear plasma device. The present study helps to characterize the geometries of a conventional poloidal divertor and advanced divertors, e.g., super-X divertor. The total ion particle flux measured with a large-diameter target plate dramatically changed under the detached plasma condition compared to that in attached plasma. Under the detached plasma condition, the magnetically expanding plasma clearly exhibited a significant influence on the degradation of detached plasma formation. Further, the magnetically contracting plasma slightly enhanced the electron-ion recombination (EIR) processes. By changing the magnetic field structure from contraction to expansion, the electron density (ne) decreased and the electron temperature (Te) increased upstream from the recombination front, leading to the degradation of the EIR processes. The effect of the decrease in parallel flow velocity under the magnetically contracting plasma on the plasma detachment was not observed because the driven flow due to pressure gradient compensated the effect.","subitem_description_type":"Abstract"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"AIP Publishing"}]},"item_10001_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1063/1.4986100","subitem_relation_type_select":"DOI"}}]},"item_10001_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"Publisher version"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1063/1.4986100","subitem_relation_type_select":"DOI"}}]},"item_10001_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"This article may be downloaded for personal use only. Any other use requires prior permission of the author and AIP Publishing. This article appeared in Physics of Plasmas 24, 062509 (2017) and may be found at https://doi.org/10.1063/1.4986100."},{"subitem_rights":"The following article has been accepted by Physics of Plasmas After it is published, it will be found at https://aip.scitation.org/doi/10.1063/1.4986100."},{"subitem_rights":"Copyright 2017 Author(s). This article is distributed under a Creative Commons Attribution (CC BY) License.”"}]},"item_10001_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA10987555 ","subitem_source_identifier_type":"NCID"}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1070-664X","subitem_source_identifier_type":"ISSN"}]},"item_10001_text_23":{"attribute_name":"NAIS","attribute_value_mlt":[{"subitem_text_value":"|||"}]},"item_10001_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Hayashi, Yuki"}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"OHNO, Noriyasu"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"KAJITA, Shin"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"TANAKA, Hirohiko"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2022-03-15"}],"displaytype":"detail","filename":"Phys.Plasmas24_062509.pdf","filesize":[{"value":"1.3 MB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"Phys.Plasmas24_062509","url":"https://nifs-repository.repo.nii.ac.jp/record/10548/files/Phys.Plasmas24_062509.pdf"},"version_id":"5b049a79-19c1-457b-bab3-748f19521174"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Influence of expanding and contracting magnetic field configurations on detached plasma formation in a linear plasma device","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Influence of expanding and contracting magnetic field configurations on detached plasma formation in a linear plasma device"}]},"item_type_id":"10001","owner":"19","path":["7"],"pubdate":{"attribute_name":"公開日","attribute_value":"2021-06-30"},"publish_date":"2021-06-30","publish_status":"0","recid":"10548","relation_version_is_last":true,"title":["Influence of expanding and contracting magnetic field configurations on detached plasma formation in a linear plasma device"],"weko_creator_id":"19","weko_shared_id":19},"updated":"2023-08-01T06:57:32.346034+00:00"}