@article{oai:nifs-repository.repo.nii.ac.jp:00010595, author = {Hamaguchi, Shinji and Iwamoto, Akifumi and Takahata, Kazuya and Takada, Suguru and Imagawa, Shinsaku and Mito, Toshiyuki and Moriuchi, Sadatomo and Oba, Kouki and TAKAMI, Shigeyuki and Higaki, H. and Kumaki, T. and Nadehara, K.}, issue = {3}, journal = {IEEE Transactions on Applied Superconductivity}, month = {Feb}, note = {The superconducting magnet test facility in the National Institute for Fusion Science has been upgraded for excitation tests at a wide temperature range and a higher magnetic field of 13 T. As part of the upgrade, the helium refrigerator/liquefier that operated for 24 years was replaced with a variable-temperature helium refrigerator/liquefier. The required liquefaction rate is 250 L/h, and the required refrigeration capacity is 600 W at 4.5 K, same as the previous one. In addition, it has a new feature that can supply helium gas of a wide temperature range. The typical design cooling capacity is 1 kW under the condition of 20-K supply/30-K return and 1.5 kW under the condition of 40-K supply/50-K return. After the replacement, a series of commissioning tests were performed under the various operational conditions. From the results, the satisfactory thermodynamic performance was confirmed. In the future, it is expected that the substantial progress will be made in the development of large-scale superconducting magnets with advanced superconductors such as high-temperature superconductors and MgB2. The design of the variable-temperature helium refrigerator/liquefier and the results of the commissioning tests are reported in detail.}, title = {Commissioning Test Results of Variable Temperature Helium Refrigerator/Liquefier for NIFS Superconducting Magnet Test Facility}, volume = {26}, year = {2016} }