{"created":"2023-06-20T15:16:55.352835+00:00","id":10680,"links":{},"metadata":{"_buckets":{"deposit":"e472cc82-fd41-4f47-8021-72dc105011b3"},"_deposit":{"created_by":19,"id":"10680","owners":[19],"pid":{"revision_id":0,"type":"depid","value":"10680"},"status":"published"},"_oai":{"id":"oai:nifs-repository.repo.nii.ac.jp:00010680","sets":["6:7"]},"author_link":["67526","123133","126515","66882"],"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2018-10-09","bibliographicIssueDateType":"Issued"},"bibliographicPageStart":"10E114","bibliographicVolumeNumber":"89","bibliographic_titles":[{"bibliographic_title":"Review of Scientific Instruments"}]}]},"item_10001_description_4":{"attribute_name":"著者ID","attribute_value_mlt":[{"subitem_description":"0000-0003-1586-1084","subitem_description_type":"Other"}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"An infrared imaging video bolometer was improved for application to a neutron environment in fusion plasma devices, i.e., the Large Helical Device (LHD). In order to calibrate the thermal characteristics of the activated foil absorber inside the plasma vacuum vessel, the remote-controlled in situ calibration system was improved with high-surface-flatness mirrors. Furthermore, the carbon coating method was improved by introducing a vacuum evaporation technique instead of the conventional spray technique to realize the coating on both sides of the absorber with reproducibility and uniformity. The optimal thickness of the coating was also determined. Owing to these coating improvements, the reproducibility of the effective emissivity on both sides especially was improved. Finally, the variation with the neutron irradiation of the thermal characteristics of the foil absorber was investigated. It was found that the effect was not significant for the total neutron emission of 3.6 × 1018 on LHD.","subitem_description_type":"Abstract"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"AIP Publishing"}]},"item_10001_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"doi.org/10.1063/1.5038947","subitem_relation_type_select":"DOI"}}]},"item_10001_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"Publosher version"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://aip.scitation.org/doi/10.1063/1.5038947","subitem_relation_type_select":"URI"}}]},"item_10001_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"This article may be downloaded for personal use only. Any other use requires prior permission of the author and AIP Publishing. This article appeared in Review of Scientific Instruments 89, 10E114 (2018) and may be found at https://aip.scitation.org/doi/abs/10.1063/1.5038947."},{"subitem_rights":"Copyright (2018) Author(s). This article is distributed under a Creative Commons Attribution (CC BY) License."}]},"item_10001_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA00817730 ","subitem_source_identifier_type":"NCID"}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"00346748","subitem_source_identifier_type":"ISSN"}]},"item_10001_text_23":{"attribute_name":"NAIS","attribute_value_mlt":[{"subitem_text_value":"|||"}]},"item_10001_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"MUKAI, Kiyofumi"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Abe, Ryo"}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"PETERSON, Byron"},{"creatorName":"PETERSON, Byron J."}],"familyNames":[{},{}],"givenNames":[{},{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"TAKAYAMA, Sadatsugu"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2021-10-29"}],"displaytype":"detail","filename":"Review_of_Scientific_Instruments89_pp10E114.pdf","filesize":[{"value":"2.0 MB"}],"format":"application/pdf","licensetype":"license_6","mimetype":"application/pdf","url":{"label":"Review_of_Scientific_Instruments89_pp10E114","url":"https://nifs-repository.repo.nii.ac.jp/record/10680/files/Review_of_Scientific_Instruments89_pp10E114.pdf"},"version_id":"375929b6-a1d3-4fc5-8531-17021da0069c"},{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2022-03-16"}],"displaytype":"detail","filename":"VoR_Rev.Sci.Instr89_10E114.pdf","filesize":[{"value":"4.1 MB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"VoR_Rev.Sci.Instr89_10E114","url":"https://nifs-repository.repo.nii.ac.jp/record/10680/files/VoR_Rev.Sci.Instr89_10E114.pdf"},"version_id":"db3d5fea-8ca7-4d02-b1de-a73c5d53b757"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Improvement of infrared imaging video bolometer for application to deuterium experiment on the large helical device","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Improvement of infrared imaging video bolometer for application to deuterium experiment on the large helical device"}]},"item_type_id":"10001","owner":"19","path":["7"],"pubdate":{"attribute_name":"公開日","attribute_value":"2021-10-29"},"publish_date":"2021-10-29","publish_status":"0","recid":"10680","relation_version_is_last":true,"title":["Improvement of infrared imaging video bolometer for application to deuterium experiment on the large helical device"],"weko_creator_id":"19","weko_shared_id":19},"updated":"2023-09-26T03:36:32.667422+00:00"}