{"created":"2023-06-20T15:17:01.084641+00:00","id":10788,"links":{},"metadata":{"_buckets":{"deposit":"e012dc2b-ada6-4ffa-83d1-ebe931a7bbae"},"_deposit":{"created_by":19,"id":"10788","owners":[19],"pid":{"revision_id":0,"type":"depid","value":"10788"},"status":"published"},"_oai":{"id":"oai:nifs-repository.repo.nii.ac.jp:00010788","sets":["6:7"]},"author_link":["126581","126661","126659","126660","126361","66533","126345","66696","126353"],"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2017-11","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"11","bibliographicPageStart":"113302","bibliographicVolumeNumber":"88","bibliographic_titles":[{"bibliographic_title":"Review of Scientific Instruments"}]}]},"item_10001_description_4":{"attribute_name":"著者ID","attribute_value_mlt":[{"subitem_description":"0000-0001-9473-3747","subitem_description_type":"Other"}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"In situ calibration of the neutron activation system on the Large Helical Device (LHD) was performed by using an intense 252Cf neutron source. To simulate a ring-shaped neutron source, we installed a railway inside the LHD vacuum vessel and made a train loaded with the 252Cf source run along a typical magnetic axis position. Three activation capsules loaded with thirty pieces of indium foils stacked with total mass of approximately 18 g were prepared. Each capsule was irradiated over 15 h while the train was circulating. The activation response coefficient (9.4 ± 1.2) × 10−8 of 115In(n, n′)115mIn reaction obtained from the experiment is in good agreement with results from three-dimensional neutron transport calculations using the Monte Carlo neutron transport simulation code 6. The activation response coefficients of 2.45 MeV birth neutron and secondary 14.1 MeV neutron from deuterium plasma were evaluated from the activation response coefficient obtained in this calibration experiment with results from three-dimensional neutron calculations using the Monte Carlo neutron transport simulation code 6.","subitem_description_type":"Abstract"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"AIP Publishing"}]},"item_10001_relation_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"00346748","subitem_relation_type_select":"NCID"}}]},"item_10001_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1063/1.5009475","subitem_relation_type_select":"DOI"}}]},"item_10001_relation_16":{"attribute_name":"情報源","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"Review of Scientific Instruments 88, 113302 (2017); https://doi.org/10.1063/1.5009475"}]}]},"item_10001_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"Publisher version"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1063/1.5009475","subitem_relation_type_select":"DOI"}}]},"item_10001_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"This article may be downloaded for personal use only. Any other use requires prior permission of the author and AIP Publishing. This article appeared in Review of Scientific Instruments 88, 113302 (2017) and may be found at https://aip.scitation.org/doi/abs/10.1063/1.5009475"},{"subitem_rights":"Copyright 2021 Author(s). This article is distributed under a Creative Commons Attribution (CC BY) License. "}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"00346748","subitem_source_identifier_type":"ISSN"}]},"item_10001_text_23":{"attribute_name":"NAIS","attribute_value_mlt":[{"subitem_text_value":"|||"}]},"item_10001_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"PU, Neng"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Nishitani, Takeo"}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"ISOBE, Mitsutaka"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"OGAWA, Kunihoro"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Kawase, Hiroki"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Tanaka, T."}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Li, S. Y."}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Yoshidashi, S."}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Uritani, Akira"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2021-12-17"}],"displaytype":"detail","filename":"Rev.Sci.Instr_88_113302 .pdf","filesize":[{"value":"1.5 MB"}],"format":"application/pdf","licensetype":"license_6","mimetype":"application/pdf","url":{"label":"Rev.Sci.Instr_88_113302 ","url":"https://nifs-repository.repo.nii.ac.jp/record/10788/files/Rev.Sci.Instr_88_113302 .pdf"},"version_id":"fe71481a-d435-4be0-91e4-7c75f774382c"},{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2022-03-16"}],"displaytype":"detail","filename":"VoR_Rev.Sci.Instr88_113302.pdf","filesize":[{"value":"20.3 MB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"VoR_Rev.Sci.Instr88_113302","url":"https://nifs-repository.repo.nii.ac.jp/record/10788/files/VoR_Rev.Sci.Instr88_113302.pdf"},"version_id":"1c00275a-3d9d-48a6-9e2c-089c3ade41ca"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"In situ calibration of neutron activation system on the large helical device","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"In situ calibration of neutron activation system on the large helical device"}]},"item_type_id":"10001","owner":"19","path":["7"],"pubdate":{"attribute_name":"公開日","attribute_value":"2021-12-17"},"publish_date":"2021-12-17","publish_status":"0","recid":"10788","relation_version_is_last":true,"title":["In situ calibration of neutron activation system on the large helical device"],"weko_creator_id":"19","weko_shared_id":19},"updated":"2023-07-31T03:00:56.376407+00:00"}