{"created":"2023-06-20T15:17:02.036414+00:00","id":10806,"links":{},"metadata":{"_buckets":{"deposit":"f652161f-ac34-4509-880f-0cd5012599c2"},"_deposit":{"created_by":19,"id":"10806","owners":[19],"pid":{"revision_id":0,"type":"depid","value":"10806"},"status":"published"},"_oai":{"id":"oai:nifs-repository.repo.nii.ac.jp:00010806","sets":["6:7"]},"author_link":["126700","66751","126571","126688","126701"],"control_number":"10806","item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2021-07-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"7","bibliographicPageStart":"073501","bibliographicVolumeNumber":"92","bibliographic_titles":[{"bibliographic_title":"Review of Scientific Instruments","bibliographic_titleLang":"en"}]}]},"item_10001_description_4":{"attribute_name":"著者ID","attribute_value_mlt":[{"subitem_description":"0000-0002-6479-049X","subitem_description_type":"Other"}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Coherence imaging spectroscopy (CIS) measures the two-dimensional profiles of both ion temperature and ion velocity in plasmas. The interferometric technique is realized by a certain relation between the phase and the wavelength of light emerging from a birefringent crystal. The calibration for the CIS system requires monochromatic and tunable light sources near the He II line (468.6 nm) or C III line (465 nm) where the CIS measures. In this research, the CIS system has been upgraded by implementing an electron multiplier CCD and a CIS cell. A monochromator validates the linearity of the phase relation on the wavelength near the He II line. As an in situ calibration at the Ring Trap 1 plasma device, two spectral lines of Ti and Zn lamps obtain the accurate dispersion function of phase. It is found that a simple method with two spectral lines is reliable and sufficient for the calibration.","subitem_description_type":"Abstract"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"AIP Publishing"}]},"item_10001_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1063/5.0043875","subitem_relation_type_select":"DOI"}}]},"item_10001_relation_16":{"attribute_name":"情報源","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"Review of Scientific Instruments 92, 073501 (2021); https://doi.org/10.1063/5.0043875"}]}]},"item_10001_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"Publisher version"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1063/5.0043875","subitem_relation_type_select":"DOI"}}]},"item_10001_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"This article may be downloaded for personal use only. Any other use requires prior permission of the author and AIP Publishing. This article appeared in Review of Scientific Instruments 92, 073501 (2021) and may be found at https://aip.scitation.org/doi/abs/10.1063/5.0043875."},{"subitem_rights":"Copyright 2021 Author(s). This article is distributed under a Creative Commons Attribution (CC BY) License."}]},"item_10001_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA00817730","subitem_source_identifier_type":"NCID"}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"00346748","subitem_source_identifier_type":"ISSN"}]},"item_10001_text_23":{"attribute_name":"NAIS","attribute_value_mlt":[{"subitem_text_value":"|||"}]},"item_10001_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"UEDA, Kenji"}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{}],"affiliationNames":[{}]}],"creatorNames":[{"creatorName":"NISHIURA, Masaki"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Kenmochi, Naoki"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"yoshida, Zensho"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Nakamura, Kaori"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2021-12-20"}],"displaytype":"detail","filename":"Rev.Sci.Instr.92_pp073501.pdf","filesize":[{"value":"567.2 kB"}],"format":"application/pdf","licensetype":"license_6","mimetype":"application/pdf","url":{"label":"Rev.Sci.Instr.92_pp073501","url":"https://nifs-repository.repo.nii.ac.jp/record/10806/files/Rev.Sci.Instr.92_pp073501.pdf"},"version_id":"4458b846-4309-4143-94a2-fb260ea243fc"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Calibration of coherence imaging spectroscopy using spectral line sources","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Calibration of coherence imaging spectroscopy using spectral line sources","subitem_title_language":"en"}]},"item_type_id":"10001","owner":"19","path":["7"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2021-12-20"},"publish_date":"2021-12-20","publish_status":"0","recid":"10806","relation_version_is_last":true,"title":["Calibration of coherence imaging spectroscopy using spectral line sources"],"weko_creator_id":"19","weko_shared_id":-1},"updated":"2024-01-16T05:30:20.597257+00:00"}