{"created":"2023-06-20T15:17:02.567615+00:00","id":10813,"links":{},"metadata":{"_buckets":{"deposit":"7c05acc9-91bb-4d5c-b8a6-8ceb2ca75d85"},"_deposit":{"created_by":19,"id":"10813","owners":[19],"pid":{"revision_id":0,"type":"depid","value":"10813"},"status":"published"},"_oai":{"id":"oai:nifs-repository.repo.nii.ac.jp:00010813","sets":["6:7"]},"author_link":["126710","122527","126709","126711","126712","66882","125139"],"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2018-10-10","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"10","bibliographicPageStart":"10E115","bibliographicVolumeNumber":"89","bibliographic_titles":[{"bibliographic_title":"Review of Scientific Instruments"}]}]},"item_10001_description_4":{"attribute_name":"著者ID","attribute_value_mlt":[{"subitem_description":"0000-0002-4446-4603","subitem_description_type":"Other"}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"An InfraRed imaging Video Bolometer (IRVB) was installed on KSTAR in 2012 having a ∼2 μm × 7 cm × 9 cm Pt foil blackened with graphite and a 5 mm × 5 mm aperture located 7.65 cm from the foil with 16 × 12 channels and a time resolution of 10 ms. The IR camera was an Indigo Phoenix (InSb, 320 × 256 pixels, 435 fps, <25 mK). In 2017, the IRVB was upgraded by replacing the IR camera with a FLIR SC7600 (InSb, 640 × 512 pixels, 105 fps, <25 mK). The aperture area was reduced by approximately half to 3.5 mm × 3.5 mm, and the number of channels was quadrupled to 32 × 24. A synthetic image derived using the projection matrix for the upgraded IRVB from a Scrape Off Layer Plasma Simulator (SOLPS) model with 146 kW of total radiated power had a maximum signal of 7.6 W/m2 and a signal to noise ratio (SNR) of 11. Experimental data for a plasma with parameters similar to the SOLPS model (total radiated power of 158 kW) had a maximum signal of 12.6 W/m2 and noise equivalent power density (SNR) of 0.9 W/m2 (14).","subitem_description_type":"Abstract"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"AIP Publishing"}]},"item_10001_relation_13":{"attribute_name":"PubMed番号","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"30399667","subitem_relation_type_select":"PMID"}}]},"item_10001_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1063/1.5038935","subitem_relation_type_select":"DOI"}}]},"item_10001_relation_16":{"attribute_name":"情報源","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"Review of Scientific Instruments 89, 10E115 (2018); https://doi.org/10.1063/1.5038935"}]}]},"item_10001_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"Publisher version"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1063/1.5038935","subitem_relation_type_select":"DOI"}}]},"item_10001_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"This article may be downloaded for personal use only. Any other use requires prior permission of the author and AIP Publishing. This article appeared in Review of Scientific Instruments 89, 10E115 (2018) and may be found at https://aip.scitation.org/doi/abs/10.1063/1.5038935."},{"subitem_rights":"Copyright 2018 Author(s). This article is distributed under a Creative Commons Attribution (CC BY) License. "}]},"item_10001_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA00817730 ","subitem_source_identifier_type":"NCID"}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"00346748","subitem_source_identifier_type":"ISSN"}]},"item_10001_text_23":{"attribute_name":"NAIS","attribute_value_mlt":[{"subitem_text_value":"|||"}]},"item_10001_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"PETERSON, Byron"},{"creatorName":"PETERSON, Byron J."}],"familyNames":[{},{}],"givenNames":[{},{}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Oh, Seungtae"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"SEO, Dongcheol"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Jang, Juhyeok"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"PARK, Jae Sun"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Mukai, Kiyofumi"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Choe, Wonho"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2021-12-20"}],"displaytype":"detail","filename":"Rev.Sci.Instr.89_pp10E115.pdf","filesize":[{"value":"379.1 kB"}],"format":"application/pdf","licensetype":"license_6","mimetype":"application/pdf","url":{"label":"Rev.Sci.Instr.89_pp10E115","url":"https://nifs-repository.repo.nii.ac.jp/record/10813/files/Rev.Sci.Instr.89_pp10E115.pdf"},"version_id":"0812c4d9-f82a-4379-b734-d1d1dc445165"},{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2022-03-16"}],"displaytype":"detail","filename":"VoR_Rev.Sci.Instrum89_10E115.pdf","filesize":[{"value":"3.5 MB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"VoR_Rev.Sci.Instrum89_10E115","url":"https://nifs-repository.repo.nii.ac.jp/record/10813/files/VoR_Rev.Sci.Instrum89_10E115.pdf"},"version_id":"1adbe1e7-e6ed-4b88-b956-477511a0f7a3"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Signal to noise ratio of upgraded imaging bolometer for KSTAR","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Signal to noise ratio of upgraded imaging bolometer for KSTAR"}]},"item_type_id":"10001","owner":"19","path":["7"],"pubdate":{"attribute_name":"公開日","attribute_value":"2021-12-20"},"publish_date":"2021-12-20","publish_status":"0","recid":"10813","relation_version_is_last":true,"title":["Signal to noise ratio of upgraded imaging bolometer for KSTAR"],"weko_creator_id":"19","weko_shared_id":19},"updated":"2023-09-26T03:19:33.788970+00:00"}