{"created":"2023-06-20T15:17:03.579664+00:00","id":10833,"links":{},"metadata":{"_buckets":{"deposit":"9d953d28-707f-4e95-9b93-33a464b2fd1c"},"_deposit":{"created_by":19,"id":"10833","owners":[19],"pid":{"revision_id":0,"type":"depid","value":"10833"},"status":"published"},"_oai":{"id":"oai:nifs-repository.repo.nii.ac.jp:00010833","sets":["6:7"]},"author_link":["126727","66551","67399","66571","66554","66901","66548"],"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2016-02-03","bibliographicIssueDateType":"Issued"},"bibliographicPageStart":"C02009","bibliographicVolumeNumber":"11","bibliographic_titles":[{"bibliographic_title":"Journal of Instrumentation"}]}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"We have upgraded the multi-channel microwave reflectometer system which uses a frequency comb as a source and measure the distribution of the density fluctuation caused by magneto-hydro dynamics instability. The previous multi-channel system was composed of the Ka-band, and the U-band system has been developed. Currently, the U-band system has eight frequency channels, which are 43.0, 45.0, 47.0, 49.0, 51.0, 53.0, 55.0, and 57.0 GHz, in U-band. Before the installation to the Large Helical Device (LHD), several tests for understanding the system characteristics, which are the phase responsibility, the linearity of output signal, and others, have been carried out. The in situ calibration in LHD has been done for the cross reference. In the neutral beam injected plasma experiments, we can observe the density fluctuation of the interchange mode and obtain the radial distribution of fluctuation amplitude. ","subitem_description_type":"Abstract"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"IOP Publishing"}]},"item_10001_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1088/1748-0221/11/02/C02009","subitem_relation_type_select":"DOI"}}]},"item_10001_relation_16":{"attribute_name":"情報源","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"Citation R. Soga et al 2016 JINST 11 C02009"}]}]},"item_10001_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"Publisher version"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1088/1748-0221/11/02/C02009","subitem_relation_type_select":"DOI"}}]},"item_10001_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"This is the Accepted Manuscript version of an article accepted for publication in Journal of Instrumentation. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The Version of Record is available online at https://doi.org/10.1088/1748-0221/11/02/C02009."}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"17480221","subitem_source_identifier_type":"ISSN"}]},"item_10001_text_23":{"attribute_name":"NAIS","attribute_value_mlt":[{"subitem_text_value":"|||"}]},"item_10001_text_25":{"attribute_name":"書誌的事項","attribute_value_mlt":[{"subitem_text_value":"17th International Symposium on Laser-Aided Plasma Diagnostics (LAPD17)"}]},"item_10001_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Soga, R."}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"TOKUZAWA, Tokihiko"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"WATANABE, Kiyomasa"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"TANAKA, Kenji"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"YAMADA, Ichihiro"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"INAGAKI, Shigeru"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"KASUYA, Naohiro"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2021-12-21"}],"displaytype":"detail","filename":"J.Instrumentation_11_C02009.pdf","filesize":[{"value":"807.8 kB"}],"format":"application/pdf","licensetype":"license_6","mimetype":"application/pdf","url":{"label":"J.Instrumentation_11_C02009","url":"https://nifs-repository.repo.nii.ac.jp/record/10833/files/J.Instrumentation_11_C02009.pdf"},"version_id":"454ba191-9f31-4b85-91bf-2bd7c47716fd"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Plasma diagnostics - interferometry","subitem_subject_scheme":"Other"},{"subitem_subject":"spectroscopy and imaging","subitem_subject_scheme":"Other"},{"subitem_subject":"Nuclear instruments and methods for hot plasma diagnostics","subitem_subject_scheme":"Other"},{"subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Developments of frequency comb microwave reflectometer for the interchange mode observations in LHD plasma","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Developments of frequency comb microwave reflectometer for the interchange mode observations in LHD plasma"}]},"item_type_id":"10001","owner":"19","path":["7"],"pubdate":{"attribute_name":"公開日","attribute_value":"2021-12-21"},"publish_date":"2021-12-21","publish_status":"0","recid":"10833","relation_version_is_last":true,"title":["Developments of frequency comb microwave reflectometer for the interchange mode observations in LHD plasma"],"weko_creator_id":"19","weko_shared_id":19},"updated":"2024-04-24T06:42:19.190501+00:00"}