{"created":"2023-06-20T15:17:05.319198+00:00","id":10864,"links":{},"metadata":{"_buckets":{"deposit":"637388d2-6fc0-40f9-8aa0-449af4f2b7b8"},"_deposit":{"created_by":19,"id":"10864","owners":[19],"pid":{"revision_id":0,"type":"depid","value":"10864"},"status":"published"},"_oai":{"id":"oai:nifs-repository.repo.nii.ac.jp:00010864","sets":["6:7"]},"author_link":["126839","126835","126837","126838","66777","126836","126840","66901"],"control_number":"10864","item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2020-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageStart":"014704","bibliographicVolumeNumber":"91","bibliographic_titles":[{"bibliographic_title":"Review of Scientific Instruments"}]}]},"item_10001_description_4":{"attribute_name":"著者ID","attribute_value_mlt":[{"subitem_description":"0000-0002-9298-5585","subitem_description_type":"Other"}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"In this paper, we present noncontact and noninvasive vital signal detection using a microwave reflectometer. Elimination of noise components due to random movement of human subjects has been the biggest issue for microwave measurement. Appropriate filtering, amplitude control of the reflectometer signal, and cross correlation among multiple reflectometers together with new algorithms have enabled motion artifact elimination, signal peak detection, and data processing for various parameters related to heart rate (HR) and heart rate variability (HRV). We focus here on the real time measurements of instantaneous HR and HRV for practical use. The evaluation by microwave reflectometry is completely noninvasive and feasible even through clothing, which is extremely effective for health maintenance in daily life as well as for preventing sudden death related to, for example, coronary heart disease and ventricular arrhythmia.","subitem_description_type":"Abstract"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"AIP Publishing"}]},"item_10001_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1063/1.5128959","subitem_relation_type_select":"DOI"}}]},"item_10001_relation_16":{"attribute_name":"情報源","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"Review of Scientific Instruments 91, 014704 (2020); https://doi.org/10.1063/1.5128959"}]}]},"item_10001_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"Publisher version"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1063/1.5128959","subitem_relation_type_select":"DOI"}}]},"item_10001_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"This article may be downloaded for personal use only. Any other use requires prior permission of the author and AIP Publishing. This article appeared in Review of Scientific Instruments 91, 014704 (2020); and may be found at https://aip.scitation.org/doi/abs/10.1063/1.5128959."}]},"item_10001_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA00817730","subitem_source_identifier_type":"NCID"}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"00346748","subitem_source_identifier_type":"ISSN"}]},"item_10001_text_23":{"attribute_name":"NAIS","attribute_value_mlt":[{"subitem_text_value":"|||"}]},"item_10001_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"MASE, Atsushi"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"KOGA, Y."}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"MARUYAMA, T."}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"TOKUZAWA, Tokihiko"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"SAKAI, F."}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"KUNUGITA, M."}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"KOIKE, T."}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"HASEGAWA, H."}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2021-12-23"}],"displaytype":"detail","filename":"Rev.Sci.Instrum91_pp014704.pdf","filesize":[{"value":"2.1 MB"}],"format":"application/pdf","licensetype":"license_6","mimetype":"application/pdf","url":{"label":"Rev.Sci.Instrum91_pp014704","url":"https://nifs-repository.repo.nii.ac.jp/record/10864/files/Rev.Sci.Instrum91_pp014704.pdf"},"version_id":"614e8193-2548-4ec3-a41f-7dfa8cce1c17"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Non-contact and real-time measurement of heart rate and heart rate variability using microwave reflectometry","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Non-contact and real-time measurement of heart rate and heart rate variability using microwave reflectometry","subitem_title_language":"en"}]},"item_type_id":"10001","owner":"19","path":["7"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2021-12-23"},"publish_date":"2021-12-23","publish_status":"0","recid":"10864","relation_version_is_last":true,"title":["Non-contact and real-time measurement of heart rate and heart rate variability using microwave reflectometry"],"weko_creator_id":"19","weko_shared_id":-1},"updated":"2024-04-23T05:35:08.242957+00:00"}