{"created":"2023-06-20T15:17:12.440538+00:00","id":11010,"links":{},"metadata":{"_buckets":{"deposit":"b0776d85-a000-41ea-bc64-0689eaa48e61"},"_deposit":{"created_by":20,"id":"11010","owners":[20],"pid":{"revision_id":0,"type":"depid","value":"11010"},"status":"published"},"_oai":{"id":"oai:nifs-repository.repo.nii.ac.jp:00011010","sets":["6:7"]},"author_link":["127013","127039","123165","122867"],"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2018-05-10","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"Special Issue 2","bibliographicPageStart":"3405038","bibliographicVolumeNumber":"13","bibliographic_titles":[{"bibliographic_title":"Plasma and Fusion Research"}]}]},"item_10001_description_4":{"attribute_name":"著者ID","attribute_value_mlt":[{"subitem_description":"0000-0001-9941-1958","subitem_description_type":"Other"}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"From the viewpoints of radiation management and public acceptance, the monitoring of tritium concentration in the stack is one of the key issues for the deuterium plasma experiment in the Large Helical Device (LHD). Since 2012, an active tritium sampler was employed in the stack to monitor the background levels of tritium and discriminate between its chemical forms. However, the operation procedure became complicated, so we developed a simplified active tritium sampler to reduce the work after sampling. In this sampler system, there was no discrimination between tritium chemical forms, instead, all tritium chemical forms were collected in one process. To verify the performance of the simplified active tritium sampler, tritium concentration data was compared with the existing tritium active sampler and environmental tritium data at the NIFS site. The results revealed a correlation between these tritium data. Therefore, the simplified active tritium sampler was applied in the stack with a primary monitoring system for the deuterium plasma experiment in the LHD.","subitem_description_type":"Abstract"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"The Japan Society of Plasma Science and Nuclear Fusion Research "}]},"item_10001_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1585/pfr.13.3405038 ","subitem_relation_type_select":"DOI"}}]},"item_10001_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"Publisher version"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":" https://doi.org/10.1585/pfr.13.3405038 ","subitem_relation_type_select":"DOI"}}]},"item_10001_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"(c) 2018 The Japan Society of Plasma Science and Nuclear Fusion Research "}]},"item_10001_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA12346675","subitem_source_identifier_type":"NCID"}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1880-6821","subitem_source_identifier_type":"ISSN"}]},"item_10001_text_23":{"attribute_name":"NAIS","attribute_value_mlt":[{"subitem_text_value":"|||"}]},"item_10001_text_25":{"attribute_name":"書誌的事項","attribute_value_mlt":[{"subitem_text_value":"the 26th International Toki Conference (ITC-26) —New Era in Plasma and Fusion Research— & the 11th Asia Plasma and Fusion Association Conference (APFA-11)"}]},"item_10001_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"TANAKA, Masahiro"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"YAMAMOTO, Yukie"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"IWATA, Chie"}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"AKATA, Naofumi"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2022-02-03"}],"displaytype":"detail","filename":"pfr2018_13-3405038.pdf","filesize":[{"value":"923.7 kB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"pfr2018_13-3405038","url":"https://nifs-repository.repo.nii.ac.jp/record/11010/files/pfr2018_13-3405038.pdf"},"version_id":"4b1c376b-1f4f-48d9-9f23-890862ea844b"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"tritium monitoring","subitem_subject_scheme":"Other"},{"subitem_subject":"active tritium sampler","subitem_subject_scheme":"Other"},{"subitem_subject":"fusion test facility","subitem_subject_scheme":"Other"},{"subitem_subject":"radiation management","subitem_subject_scheme":"Other"},{"subitem_subject":"deuterium plasma experiment","subitem_subject_scheme":"Other"},{"subitem_subject":"large fusion test device","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Monitoring of Tritium Concentration by Simplified Active Sampler in a Fusion Test Facility","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Monitoring of Tritium Concentration by Simplified Active Sampler in a Fusion Test Facility"}]},"item_type_id":"10001","owner":"20","path":["7"],"pubdate":{"attribute_name":"公開日","attribute_value":"2022-02-03"},"publish_date":"2022-02-03","publish_status":"0","recid":"11010","relation_version_is_last":true,"title":["Monitoring of Tritium Concentration by Simplified Active Sampler in a Fusion Test Facility"],"weko_creator_id":"20","weko_shared_id":20},"updated":"2023-09-29T04:35:56.117296+00:00"}