{"created":"2023-06-20T15:17:15.889324+00:00","id":11090,"links":{},"metadata":{"_buckets":{"deposit":"432192e6-fcda-4f6b-b820-63e31e05bd78"},"_deposit":{"created_by":20,"id":"11090","owners":[20],"pid":{"revision_id":0,"type":"depid","value":"11090"},"status":"published"},"_oai":{"id":"oai:nifs-repository.repo.nii.ac.jp:00011090","sets":["6:7"]},"author_link":["127205","66594","66600","66755","66751","66754","126267","66603","66598","66524"],"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2021-06-07","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"Special Issue 1","bibliographicPageStart":"2405066","bibliographicVolumeNumber":"16","bibliographic_titles":[{"bibliographic_title":"Plasma and Fusion Research"}]}]},"item_10001_description_4":{"attribute_name":"著者ID","attribute_value_mlt":[{"subitem_description":"0000-0002-4541-1757","subitem_description_type":"Other"}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Alignment of the quasi-optical millimeter wave antenna for the electron cyclotron resonance heating (ECRH) can be required even after the evacuation of the vacuum vessel in fusion oriented plasma experimental devices. We developed a molybdenum millimeter wave target tile and installed it as one of the protection tiles of the vacuum vessel wall of the Large Helical Device (LHD) on the opposite side of the ECRH antennas. Inside the target tile, a sheathed thermocouple is mounted to measure the temperature increase during the millimeter wave injection toward this tile. In magnetic field configurations where neither the first nor the second electron cyclotron resonance (ECR) exists, the measured temperature increased sufficiently to be detected by the millimeter wave injection of approximately 100 kW for 0.1 s toward the target tile. Under the assumption that the distance between the target point that brings the largest temperature increase and the target point just above the thermocouple head gives the offset of the target point to be corrected, the offset of the antenna injection angle was confirmed with an accuracy of 0.4° with changing the target point shot by shot.","subitem_description_type":"Abstract"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"The Japan Society of Plasma Science and Nuclear Fusion Research "}]},"item_10001_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1585/pfr.16.2405066 ","subitem_relation_type_select":"DOI"}}]},"item_10001_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"Publisher version"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":" https://doi.org/10.1585/pfr.16.2405066 ","subitem_relation_type_select":"DOI"}}]},"item_10001_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"(c) 2021 The Japan Society of Plasma Science and Nuclear Fusion Research "}]},"item_10001_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA12346675","subitem_source_identifier_type":"NCID"}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1880-6821","subitem_source_identifier_type":"ISSN"}]},"item_10001_text_23":{"attribute_name":"NAIS","attribute_value_mlt":[{"subitem_text_value":"|||"}]},"item_10001_text_25":{"attribute_name":"書誌的事項","attribute_value_mlt":[{"subitem_text_value":"the 29th International Toki Conference on Plasma and Fusion Research (ITC29) "}]},"item_10001_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"IGAMI, Hiroe"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"YANAI, Ryoma"},{"creatorName":"YANAI, Ryohma"}],"familyNames":[{},{}],"givenNames":[{},{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"ITO, Satoshi"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"YOSHIMURA, Yasuo"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"KUBO, Shin"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"TAKAHASHI, Hiromi"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"SHIMOZUMA, Takashi"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"TSUJIMIRA, Toru"},{"creatorName":"TSUJIMURA, Toru Ii"}],"familyNames":[{},{}],"givenNames":[{},{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"NISHIURA, Masaki"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"MIZUNO, Yoshinori"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2022-02-17"}],"displaytype":"detail","filename":"pfr2021_16-2405066.pdf","filesize":[{"value":"10.0 MB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"pfr2021_16-2405066","url":"https://nifs-repository.repo.nii.ac.jp/record/11090/files/pfr2021_16-2405066.pdf"},"version_id":"69597296-ce65-433b-866e-565faaa15e23"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"ECRH","subitem_subject_scheme":"Other"},{"subitem_subject":"antenna alignment","subitem_subject_scheme":"Other"},{"subitem_subject":"millimeter wave target","subitem_subject_scheme":"Other"},{"subitem_subject":"thermal diffusion analysis","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Development of the Molybdenum Millimeter Wave Target Tile for ECRH Antenna Alignment after the Evacuation in LHD","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Development of the Molybdenum Millimeter Wave Target Tile for ECRH Antenna Alignment after the Evacuation in LHD"}]},"item_type_id":"10001","owner":"20","path":["7"],"pubdate":{"attribute_name":"公開日","attribute_value":"2022-02-17"},"publish_date":"2022-02-17","publish_status":"0","recid":"11090","relation_version_is_last":true,"title":["Development of the Molybdenum Millimeter Wave Target Tile for ECRH Antenna Alignment after the Evacuation in LHD"],"weko_creator_id":"20","weko_shared_id":20},"updated":"2023-09-26T05:48:26.557282+00:00"}