{"created":"2023-06-20T15:17:18.916839+00:00","id":11165,"links":{},"metadata":{"_buckets":{"deposit":"f63b6fde-9264-4106-afca-a2bb6ecede7e"},"_deposit":{"created_by":20,"id":"11165","owners":[20],"pid":{"revision_id":0,"type":"depid","value":"11165"},"status":"published"},"_oai":{"id":"oai:nifs-repository.repo.nii.ac.jp:00011165","sets":["6:7"]},"author_link":["127205","67642","127344","66600","66594","127345","126334","66751","66551","67058"],"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2022-05-02","bibliographicIssueDateType":"Issued"},"bibliographicPageStart":"053501","bibliographicVolumeNumber":"93","bibliographic_titles":[{"bibliographic_title":"Review of Scientific Instruments"}]}]},"item_10001_description_4":{"attribute_name":"著者ID","attribute_value_mlt":[{"subitem_description":"0000-0002-2752-3333 ","subitem_description_type":"Other"}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"A collective Thomson scattering (CTS) diagnostic with a ±3 GHz band around a 77 GHz gyrotron probe beam was developed to measure the velocity distribution of bulk and fast ions in high-temperature plasmas. We propose a new in situ calibration method for a CTS diagnostic system combined with a raytracing code. The method is applied in two situations for electron cyclotron emission in plasmas and in a CTS diagnostic with a modulated probe beam. Experimental results highlight the importance of refraction correction in probe and receive beams. The CTS spectrum is measured with the in situ calibrated CTS receiver and responds to fast ions originating from a tangential neutral beam with an energy of 170 keV and from a perpendicular beam with an energy of 60 keV, both in the large helical device. From a velocity space analysis model, the results elucidate the measured anisotropic CTS spectrum caused by fast ions. The calibration methods and analyses demonstrated here are essential for CTS, millimeter-wave diagnostics, and electron cyclotron heating required under fusion reactor conditions.","subitem_description_type":"Abstract"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"American Institute of Physics"}]},"item_10001_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1063/5.0079296","subitem_relation_type_select":"DOI"}}]},"item_10001_relation_16":{"attribute_name":"情報源","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"Masaki Nishiura, Shun Adachi, Kenji Tanaka, Shin Kubo, Naoki Kenmochi, Takashi Shimozuma, Ryoma Yanai, Teruo Saito, Hideo Nuga, and Ryosuke Seki , \"Collective Thomson scattering diagnostic with in situ calibration system for velocity space analysis in large helical device\", Review of Scientific Instruments 93, 053501 (2022) https://doi.org/10.1063/5.0079296 "}]}]},"item_10001_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"Publisher version"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1063/5.0079296","subitem_relation_type_select":"DOI"}}]},"item_10001_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"This article may be downloaded for personal use only. Any other use requires prior permission of the author and AIP Publishing. This article appeared in Review of Scientific Instruments 93, 053501 (2022) and may be found at https://doi.org/10.1063/5.0079296. Copyright 2022 Author(s). This article is distributed under a Creative Commons Attribution (CC BY) License. "}]},"item_10001_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA00817730","subitem_source_identifier_type":"NCID"}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0034-6748","subitem_source_identifier_type":"ISSN"}]},"item_10001_text_23":{"attribute_name":"NAIS","attribute_value_mlt":[{"subitem_text_value":"13250"}]},"item_10001_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"NISHIURA, Masaki"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"ADACHI, Shun"}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"TANAKA, Kenji"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"KUBO, Shin"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"KENMOCHI, Naoki"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"SHIMOZUMA, Takashi"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"YANAI, Ryoma"},{"creatorName":"YANAI, Ryohma"}],"familyNames":[{},{}],"givenNames":[{},{}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"SAITO, Teruo"}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"NUGA, Hideo"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"SEKI, Ryosuke"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2022-05-06"}],"displaytype":"detail","filename":"repository_13250_paper.pdf","filesize":[{"value":"1.6 MB"}],"format":"application/pdf","licensetype":"license_6","mimetype":"application/pdf","url":{"label":"repository_13250_paper","url":"https://nifs-repository.repo.nii.ac.jp/record/11165/files/repository_13250_paper.pdf"},"version_id":"15938693-b301-4693-9e6c-204aa2bf49b7"},{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2023-05-02"}],"displaytype":"detail","filename":"VoR_Rev.Sci.Instrum_93_053501.pdf","filesize":[{"value":"6.6 MB"}],"format":"application/pdf","licensetype":"license_6","mimetype":"application/pdf","url":{"label":"VoR_Rev.Sci.Instrum_93_053501","url":"https://nifs-repository.repo.nii.ac.jp/record/11165/files/VoR_Rev.Sci.Instrum_93_053501.pdf"},"version_id":"b183869f-28d2-4aab-a965-a4756453e12f"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Collective Thomson scattering diagnostic with in situ calibration system for velocity space analysis in large helical device","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Collective Thomson scattering diagnostic with in situ calibration system for velocity space analysis in large helical device"}]},"item_type_id":"10001","owner":"20","path":["7"],"pubdate":{"attribute_name":"公開日","attribute_value":"2022-05-06"},"publish_date":"2022-05-06","publish_status":"0","recid":"11165","relation_version_is_last":true,"title":["Collective Thomson scattering diagnostic with in situ calibration system for velocity space analysis in large helical device"],"weko_creator_id":"20","weko_shared_id":-1},"updated":"2023-09-26T05:48:27.385877+00:00"}