{"created":"2023-06-20T15:17:21.132421+00:00","id":11212,"links":{},"metadata":{"_buckets":{"deposit":"c7d7195e-731e-4346-9daf-e90cd2656794"},"_deposit":{"created_by":20,"id":"11212","owners":[20],"pid":{"revision_id":0,"type":"depid","value":"11212"},"status":"published"},"_oai":{"id":"oai:nifs-repository.repo.nii.ac.jp:00011212","sets":["6:7"]},"author_link":["122732","127445","127119","66515"],"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2019","bibliographicIssueDateType":"Issued"},"bibliographicPageStart":"012065","bibliographicVolumeNumber":"1293","bibliographic_titles":[{"bibliographic_title":" Journal of Physics: Conference Series"}]}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"High Temperature Superconductors (HTS) improve upon low temperature superconductors in many ways and the ability to cope with a non-uniform current distribution might be one of those improvements. To put this to the test, an experimental setup is designed to force a non-uniform current upon a stack of 5 HTS tapes, using a worst case current feeding method. The experiment can help determine the potential of this conductor design and is part of the ongoing effort to develop a non-transposed stacked HTS conductor for the nuclear fusion reactor FFHR. The results clearly show that the conductor sample is able to stably conduct a current equal to its critical current, although at an elevated electric field of roughly 5 mV/m. This means non-transposed stacked tape conductors remain stable, even if a worst case nonuniform current is constantly forced upon them. A hypothesis to explain this abnormally high electric field is formulated on the basis of the results, however additional research is needed to verify it. It states that the electric field is necessary for the tapes to share current and would mean that in a properly engineered application, these losses due to the electric field, would only occur during start-up. Overall it is clear that this experiment proves the excellent stability of non-transposed stacked HTS tapes and their ability to conduct a non-uniform current.","subitem_description_type":"Abstract"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"IOP Publishing "}]},"item_10001_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1088/1742-6596/1293/1/012065","subitem_relation_type_select":"DOI"}}]},"item_10001_relation_16":{"attribute_name":"情報源","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"T A J Meulenbroeks et al 2019 J. Phys.: Conf. Ser. 1293 012065"}]}]},"item_10001_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"Publisher version"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1088/1742-6596/1293/1/012065","subitem_relation_type_select":"DOI"}}]},"item_10001_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI."}]},"item_10001_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA12839617","subitem_source_identifier_type":"NCID"}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1742-6588","subitem_source_identifier_type":"ISSN"}]},"item_10001_text_25":{"attribute_name":"書誌的事項","attribute_value_mlt":[{"subitem_text_value":" 31st International Symposium on Superconductivity (ISS2018) 12–14 December 2018, Tsukuba, Ibaraki, Japan"}]},"item_10001_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"MEULENBROEKS, TAJ"}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"TERAZAKI, Yoshiro"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"MATSUNAGA, Shinnosuke"}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"YANAGI, Nagato"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2022-05-18"}],"displaytype":"detail","filename":"Meulenbroeks_2019_J._Phys. _Conf._Ser._1293_012065.pdf","filesize":[{"value":"1.8 MB"}],"format":"application/pdf","licensetype":"license_6","mimetype":"application/pdf","url":{"label":"Meulenbroeks_2019_J._Phys. _Conf._Ser._1293_012065","url":"https://nifs-repository.repo.nii.ac.jp/record/11212/files/Meulenbroeks_2019_J._Phys. _Conf._Ser._1293_012065.pdf"},"version_id":"ee235b7e-edc4-4bcc-9425-1eb68ec0c372"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Observation of a non-uniform current distribution in stacked high temperature superconducting tapes","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Observation of a non-uniform current distribution in stacked high temperature superconducting tapes"}]},"item_type_id":"10001","owner":"20","path":["7"],"pubdate":{"attribute_name":"公開日","attribute_value":"2022-05-18"},"publish_date":"2022-05-18","publish_status":"0","recid":"11212","relation_version_is_last":true,"title":["Observation of a non-uniform current distribution in stacked high temperature superconducting tapes"],"weko_creator_id":"20","weko_shared_id":-1},"updated":"2023-09-01T00:44:13.677328+00:00"}