{"created":"2023-06-20T15:17:28.520932+00:00","id":11376,"links":{},"metadata":{"_buckets":{"deposit":"8bc49015-3ea8-4f0a-b990-06f463c72eb3"},"_deposit":{"created_by":20,"id":"11376","owners":[20],"pid":{"revision_id":0,"type":"depid","value":"11376"},"status":"published"},"_oai":{"id":"oai:nifs-repository.repo.nii.ac.jp:00011376","sets":["6:7"]},"author_link":["67436","126930","126865","66533","126345","127641"],"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2017-09-13","bibliographicIssueDateType":"Issued"},"bibliographicPageStart":"1202036","bibliographicVolumeNumber":"12","bibliographic_titles":[{"bibliographic_title":"Plasma and Fusion Research "}]}]},"item_10001_description_4":{"attribute_name":"著者ID","attribute_value_mlt":[{"subitem_description":"0000-0003-4555-1837","subitem_description_type":"Other"}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Total neutron emission rate from Large Helical Device plasmas is measured by using a neutron flux monitor newly installed for deuterium operations. Deuteron temperature is derived from the total neutron emission rates in electron cyclotron heated Large Helical Device plasmas. Time evolution of central deuteron temperature obtained by the neutron flux monitor approximately agrees with central impurity ion temperature measured by the EUV spectrometer.","subitem_description_type":"Abstract"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"The Japan Society of Plasma Science and Nuclear Fusion Research "}]},"item_10001_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1585/pfr.12.1202036 ","subitem_relation_type_select":"DOI"}}]},"item_10001_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"Publisher version"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1585/pfr.12.1202036","subitem_relation_type_select":"DOI"}}]},"item_10001_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"(c) 2017 The Japan Society of Plasma Science and Nuclear Fusion Research "}]},"item_10001_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA12346675","subitem_source_identifier_type":"NCID"}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1880-6821","subitem_source_identifier_type":"ISSN"}]},"item_10001_text_23":{"attribute_name":"NAIS","attribute_value_mlt":[{"subitem_text_value":"10874"}]},"item_10001_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"OGAWA, Kunihiro"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"ISOBE, Mitsutaka"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"NISHITANI, Takeo"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"KAWASE, Hiroki"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"PU, Neng"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"LHD Experiment Group"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2022-06-28"}],"displaytype":"detail","filename":"10874_PFR.pdf","filesize":[{"value":"388.0 kB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"10874_PFR","url":"https://nifs-repository.repo.nii.ac.jp/record/11376/files/10874_PFR.pdf"},"version_id":"a9967481-5538-4f44-988d-0326f53ee3e9"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"neutron diagnostics","subitem_subject_scheme":"Other"},{"subitem_subject":"total neutron emission rate","subitem_subject_scheme":"Other"},{"subitem_subject":"deuteron temperature","subitem_subject_scheme":"Other"},{"subitem_subject":"LHD","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Central Deuteron Temperature Derived from Total Neutron Emission Rate in Electron Cyclotron Heated LHD Plasmas","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Central Deuteron Temperature Derived from Total Neutron Emission Rate in Electron Cyclotron Heated LHD Plasmas"}]},"item_type_id":"10001","owner":"20","path":["7"],"pubdate":{"attribute_name":"公開日","attribute_value":"2022-06-28"},"publish_date":"2022-06-28","publish_status":"0","recid":"11376","relation_version_is_last":true,"title":["Central Deuteron Temperature Derived from Total Neutron Emission Rate in Electron Cyclotron Heated LHD Plasmas"],"weko_creator_id":"20","weko_shared_id":-1},"updated":"2023-07-31T03:01:18.152006+00:00"}