{"created":"2023-06-20T15:17:30.107274+00:00","id":11412,"links":{},"metadata":{"_buckets":{"deposit":"8330d736-1a10-4a74-9322-98f3ab9bf0ac"},"_deposit":{"created_by":20,"id":"11412","owners":[20],"pid":{"revision_id":0,"type":"depid","value":"11412"},"status":"published"},"_oai":{"id":"oai:nifs-repository.repo.nii.ac.jp:00011412","sets":["6:7"]},"author_link":["66776","66775","66788","127723"],"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2016-03-17","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"Special Issue 1","bibliographicPageStart":"2405027","bibliographicVolumeNumber":"11","bibliographic_titles":[{"bibliographic_title":"Plasma and Fusion Research "}]}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"This paper reports characteristic evaluations of perforated metal sheet type high pass filters for milli- or microwave by numerical analysis and the guiding principle of designing broad-band high pass filters. The broad-band filters will be used for the microwave plasma diagnostics such as ECE, interferometer and reflectometer. We used 3D-modeling electromagnetic field calculation code to take complex interferences into account. The validity of the numerical analysis is guaranteed by a good agreement between calculated results and measured results. It is found that the frequency characteristic over the cut-off frequency depends on the filter thickness and that a thin filter is desirable for the ideal broad-band frequency filter.","subitem_description_type":"Abstract"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"The Japan Society of Plasma Science and Nuclear Fusion Research "}]},"item_10001_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1585/pfr.11.2405027 ","subitem_relation_type_select":"DOI"}}]},"item_10001_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"Publisher version"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1585/pfr.11.2405027","subitem_relation_type_select":"DOI"}}]},"item_10001_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"(c) 2016 The Japan Society of Plasma Science and Nuclear Fusion Research "}]},"item_10001_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA12346675","subitem_source_identifier_type":"NCID"}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1880-6821","subitem_source_identifier_type":"ISSN"}]},"item_10001_text_23":{"attribute_name":"NAIS","attribute_value_mlt":[{"subitem_text_value":"10455"}]},"item_10001_text_25":{"attribute_name":"書誌的事項","attribute_value_mlt":[{"subitem_text_value":"the 25th International Toki Conference on Creating the Future – Innovative Science of Plasma and Fusion – "}]},"item_10001_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"TANI, Akira"}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"TSUCHIYA, Hayato"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"KOGA, Mayuko"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"NAGAYAMA, Yoshio"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2022-07-05"}],"displaytype":"detail","filename":"10455_PFR.pdf","filesize":[{"value":"683.9 kB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"10455_PFR","url":"https://nifs-repository.repo.nii.ac.jp/record/11412/files/10455_PFR.pdf"},"version_id":"2dd21f7c-79df-44ee-94dd-76f9bb12e9a9"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"ECE","subitem_subject_scheme":"Other"},{"subitem_subject":"microwave diagnostics","subitem_subject_scheme":"Other"},{"subitem_subject":"millimetric-wave","subitem_subject_scheme":"Other"},{"subitem_subject":"perforated metal sheet","subitem_subject_scheme":"Other"},{"subitem_subject":"broad-band high pass filter","subitem_subject_scheme":"Other"},{"subitem_subject":"3D numerical analysis","subitem_subject_scheme":"Other"},{"subitem_subject":"Efield","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Design and Evaluation of Broad-Band High Pass Filter of Metal Perforated Sheets for Microwave Diagnostics","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Design and Evaluation of Broad-Band High Pass Filter of Metal Perforated Sheets for Microwave Diagnostics"}]},"item_type_id":"10001","owner":"20","path":["7"],"pubdate":{"attribute_name":"公開日","attribute_value":"2022-07-05"},"publish_date":"2022-07-05","publish_status":"0","recid":"11412","relation_version_is_last":true,"title":["Design and Evaluation of Broad-Band High Pass Filter of Metal Perforated Sheets for Microwave Diagnostics"],"weko_creator_id":"20","weko_shared_id":-1},"updated":"2023-09-29T04:25:05.568707+00:00"}