{"created":"2023-06-20T15:17:32.065673+00:00","id":11444,"links":{},"metadata":{"_buckets":{"deposit":"123dcae5-b30e-4a4c-bc6b-2a55220cd9b5"},"_deposit":{"created_by":20,"id":"11444","owners":[20],"pid":{"revision_id":0,"type":"depid","value":"11444"},"status":"published"},"_oai":{"id":"oai:nifs-repository.repo.nii.ac.jp:00011444","sets":["6:7"]},"author_link":["126913","127657","127726","66517","67634","66518"],"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2015-04-16","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"Special Issue 2","bibliographicPageStart":"3402031","bibliographicVolumeNumber":"10","bibliographic_titles":[{"bibliographic_title":"Plasma and Fusion Research"}]}]},"item_10001_description_4":{"attribute_name":"著者ID","attribute_value_mlt":[{"subitem_description":"0000-0002-1171-8603","subitem_description_type":"Other"}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Vacuum ultraviolet (VUV) spectra of emissions released from tungsten ions at lower ionization stages were measured in the Large Helical Device (LHD) using three 20 cm normal incidence spectrometers in the wavelength range of 300 to 2400 Å. Tungsten ions were introduced in the LHD plasma by injecting a pellet consisting of a small piece of tungsten metal and polyethylene tube. The VUV spectroscopy revealed that WVI 639.683 Å, 677.722 Å, and 639.683 × 2 Å lines were useful lines for monitoring tungsten ion behaviors because they had large intensities and were isolated from other intrinsic impurity lines. ","subitem_description_type":"Abstract"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"The Japan Society of Plasma Science and Nuclear Fusion Research "}]},"item_10001_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1585/pfr.10.3402031 ","subitem_relation_type_select":"DOI"}}]},"item_10001_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"Publisher version"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":" https://doi.org/10.1585/pfr.10.3402031","subitem_relation_type_select":"DOI"}}]},"item_10001_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"(c) 2015 The Japan Society of Plasma Science and Nuclear Fusion Research "}]},"item_10001_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA12346675","subitem_source_identifier_type":"NCID"}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1880-6821","subitem_source_identifier_type":"ISSN"}]},"item_10001_text_23":{"attribute_name":"NAIS","attribute_value_mlt":[{"subitem_text_value":"9152"}]},"item_10001_text_25":{"attribute_name":"書誌的事項","attribute_value_mlt":[{"subitem_text_value":"the 24th International Toki Conference on Expanding Horizons of Plasma and Fusion Science through Cross-Fertilization"}]},"item_10001_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"OISHI, Tetsutarou"},{"creatorName":"OISHI, Tetsutaro"}],"familyNames":[{},{}],"givenNames":[{},{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"MORITA, Shigeru"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"HUANG, Xianli"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"ZHANG, Hongming"}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"GOTO, Motoshi"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"The LHD Experiment Group, "}],"familyNames":[{}],"givenNames":[{"givenName":""}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2022-07-08"}],"displaytype":"detail","filename":"9152_PFR.pdf","filesize":[{"value":"2.5 MB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"9152_PFR","url":"https://nifs-repository.repo.nii.ac.jp/record/11444/files/9152_PFR.pdf"},"version_id":"78dfa0b9-080a-4b98-99b9-ae046cc5ebe2"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"vacuum ultraviolet","subitem_subject_scheme":"Other"},{"subitem_subject":"plasma spectroscopy","subitem_subject_scheme":"Other"},{"subitem_subject":"magnetically confined fusion","subitem_subject_scheme":"Other"},{"subitem_subject":"impurity transport","subitem_subject_scheme":"Other"},{"subitem_subject":"tungsten","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Line Spectrum of Tungsten Ions at Low Ionization Stages in Large Helical Device in Wavelength Range of 300 - 2400 Å Measured Using 20 cm Normal Incidence VUV Spectrometers","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Line Spectrum of Tungsten Ions at Low Ionization Stages in Large Helical Device in Wavelength Range of 300 - 2400 Å Measured Using 20 cm Normal Incidence VUV Spectrometers"}]},"item_type_id":"10001","owner":"20","path":["7"],"pubdate":{"attribute_name":"公開日","attribute_value":"2022-07-08"},"publish_date":"2022-07-08","publish_status":"0","recid":"11444","relation_version_is_last":true,"title":["Line Spectrum of Tungsten Ions at Low Ionization Stages in Large Helical Device in Wavelength Range of 300 - 2400 Å Measured Using 20 cm Normal Incidence VUV Spectrometers"],"weko_creator_id":"20","weko_shared_id":-1},"updated":"2023-09-26T05:53:45.229291+00:00"}