{"created":"2023-06-20T15:17:34.382467+00:00","id":11485,"links":{},"metadata":{"_buckets":{"deposit":"9928639d-f0e8-4d7a-af9d-a271134ac7ec"},"_deposit":{"created_by":20,"id":"11485","owners":[20],"pid":{"revision_id":0,"type":"depid","value":"11485"},"status":"published"},"_oai":{"id":"oai:nifs-repository.repo.nii.ac.jp:00011485","sets":["6:7"]},"author_link":["126930","123133","66274","66882","123135","66765","66269","123136"],"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2014-06-10","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"Special Issue 2","bibliographicPageStart":"3402064","bibliographicVolumeNumber":"9","bibliographic_titles":[{"bibliographic_title":"Plasma and Fusion Research "}]}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Detached (from the divertors) plasma regime is a very important operational phase for future fusion device operation and is sustained in the Large Helical Device (LHD) by applying an m/n = 1/1 resonant magnetic perturbation (RMP). The radiation from the plasma is found to be localized near the X-point of this RMP during plasma detachment which is confirmed both by the EMC3-EIRENE edge impurity transport code and experiments. This agreement motivates the establishment of a comparison between the results from the transport model and InfraRed imaging Video Bolometer (IRVB) experiments. A synthetic instrument has been developed which can simulate the radiation by tracing the sight lines through the three dimensional carbon impurity radiation results of the EMC3-EIRENE, giving a synthetic image. These synthetic images can be compared with the IRVB image obtained experimentally. Such a comparison is attempted here for two IRVBs installed on LHD for the data from the 2012 and 2013 experimental campaigns. The comparison reveals a fair amount of qualitative agreement but quantitative disagreement among both the approaches. Probable causes for the disagreement are discussed and corrective measures are suggested. ","subitem_description_type":"Abstract"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"The Japan Society of Plasma Science and Nuclear Fusion Research"}]},"item_10001_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1585/pfr.9.3402064 ","subitem_relation_type_select":"DOI"}}]},"item_10001_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"Publisher version"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1585/pfr.9.3402064","subitem_relation_type_select":"DOI"}}]},"item_10001_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"(c) 2014 The Japan Society of Plasma Science and Nuclear Fusion Research"}]},"item_10001_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA12346675","subitem_source_identifier_type":"NCID"}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1880-6821","subitem_source_identifier_type":"ISSN"}]},"item_10001_text_23":{"attribute_name":"NAIS","attribute_value_mlt":[{"subitem_text_value":"8602"}]},"item_10001_text_25":{"attribute_name":"書誌的事項","attribute_value_mlt":[{"subitem_text_value":"the 23rd International Toki Conference on Large-scale Simulation and Fusion Science"}]},"item_10001_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"PANDYA, Shwetang N"}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"PETERSON, Byron"},{"creatorName":"PETERSON, Byron J."}],"familyNames":[{},{}],"givenNames":[{},{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"KOBAYASHI, Masahiro"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"MUKAI, Kiyofumi"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"SANO, Ryuichi"}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"TANAKA, Hirohiko"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"MASUZAKI, Suguru"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"LHD Experiment Group"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2022-07-26"}],"displaytype":"detail","filename":"8602_PFR.pdf","filesize":[{"value":"1.6 MB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"8602_PFR","url":"https://nifs-repository.repo.nii.ac.jp/record/11485/files/8602_PFR.pdf"},"version_id":"74d1bc78-2208-49f4-929d-a4df258fbae7"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"IRVB","subitem_subject_scheme":"Other"},{"subitem_subject":"plasma detachment","subitem_subject_scheme":"Other"},{"subitem_subject":"radiation localization","subitem_subject_scheme":"Other"},{"subitem_subject":"resonant magnetic perturbation","subitem_subject_scheme":"Other"},{"subitem_subject":"synthetic diagnostic","subitem_subject_scheme":"Other"},{"subitem_subject":"edge transport model EMC3-EIRENE","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Measured and Modeled Radiation Profiles for LHD Plasma – A Comparison during Plasma Detachment","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Measured and Modeled Radiation Profiles for LHD Plasma – A Comparison during Plasma Detachment"}]},"item_type_id":"10001","owner":"20","path":["7"],"pubdate":{"attribute_name":"公開日","attribute_value":"2022-07-26"},"publish_date":"2022-07-26","publish_status":"0","recid":"11485","relation_version_is_last":true,"title":["Measured and Modeled Radiation Profiles for LHD Plasma – A Comparison during Plasma Detachment"],"weko_creator_id":"20","weko_shared_id":-1},"updated":"2023-09-26T03:36:29.276328+00:00"}