{"created":"2023-06-20T15:17:35.483840+00:00","id":11513,"links":{},"metadata":{"_buckets":{"deposit":"13789624-09b7-433c-84c7-dbfb3042138b"},"_deposit":{"created_by":20,"id":"11513","owners":[20],"pid":{"revision_id":0,"type":"depid","value":"11513"},"status":"published"},"_oai":{"id":"oai:nifs-repository.repo.nii.ac.jp:00011513","sets":["6:7"]},"author_link":["66594","66600","66755","66752","66754","67799","66611","66524","123868","127830"],"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2014-03-14","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"Special Issue 2","bibliographicPageStart":"3405024","bibliographicVolumeNumber":"9","bibliographic_titles":[{"bibliographic_title":"Plasma and Fusion Research"}]}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"For optimization of electron cyclotron resonance heating (ECRH), it is important to measure power and polarization states of injected millimeter-waves in real-time. Arbitrary polarization states of millimeter-waves are realized by two grating mirror polarizers set at miter-bends in the corrugated waveguide transmission system on the Large Helical Device (LHD). The polarization state of an injected millimeter-wave determines the mode excitation purity, and therefore the power absorption efficiency in plasmas. The real-time power/polarization monitor of the injected millimeter-wave is required for optimization and/or feedback control of ECRH. The real-time power/polarization monitor is under development to be installed on a miter-bend near the ECRH antenna on LHD. Amplitudes and phases of two orthogonal polarizations of injected millimeter-waves are measured to determine the power and polarization states of waves. In this paper, the design and performance test of the real-time power/polarization monitor are reported. Intensities and relative phase of two orthogonal polarizations are measured by a newly developed monitor with heterodyne interferometer and fast ADC (800 MHz) with FPGA. Hardware of the power/polarization monitor works as designed qualitatively. ","subitem_description_type":"Abstract"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"The Japan Society of Plasma Science and Nuclear Fusion Research "}]},"item_10001_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1585/pfr.9.3405024 ","subitem_relation_type_select":"DOI"}}]},"item_10001_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"publisher version"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1585/pfr.9.3405024","subitem_relation_type_select":"DOI"}}]},"item_10001_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"(c) 2014 The Japan Society of Plasma Science and Nuclear Fusion Research "}]},"item_10001_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA12346675","subitem_source_identifier_type":"NCID"}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1880-6821","subitem_source_identifier_type":"ISSN"}]},"item_10001_text_23":{"attribute_name":"NAIS","attribute_value_mlt":[{"subitem_text_value":"8613"}]},"item_10001_text_25":{"attribute_name":"書誌的事項","attribute_value_mlt":[{"subitem_text_value":"the 23rd International Toki Conference on Large-scale Simulation and Fusion Science"}]},"item_10001_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"MAKINO, Ryohei"}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"KUBO, Shin"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"KOBAYASHI, Kenya"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"KOBAYASHI, Sakuji"}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"SHIMOZUMA, Takashi"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"YOSHIMURA, Yasuo"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"IGAMI, Hiroe"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"TAKAHASHI, Hiromi"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"OGASAWARA, Shinya"}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"MUTOH, Takashi"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2022-08-04"}],"displaytype":"detail","filename":"8613_PFR.pdf","filesize":[{"value":"594.8 kB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"8613_PFR","url":"https://nifs-repository.repo.nii.ac.jp/record/11513/files/8613_PFR.pdf"},"version_id":"52272764-9fcf-4fde-81eb-f8f4bfa9dc56"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"power/polarization monitor","subitem_subject_scheme":"Other"},{"subitem_subject":"millimeter-waves","subitem_subject_scheme":"Other"},{"subitem_subject":"electron cyclotron resonance heating","subitem_subject_scheme":"Other"},{"subitem_subject":"LHD","subitem_subject_scheme":"Other"},{"subitem_subject":"miter-bend","subitem_subject_scheme":"Other"},{"subitem_subject":"FPGA","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Development of a Real-Time Power/Polarization Monitor using FPGA for Electron Cyclotron Resonance Heating on LHD","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Development of a Real-Time Power/Polarization Monitor using FPGA for Electron Cyclotron Resonance Heating on LHD"}]},"item_type_id":"10001","owner":"20","path":["7"],"pubdate":{"attribute_name":"公開日","attribute_value":"2022-08-04"},"publish_date":"2022-08-04","publish_status":"0","recid":"11513","relation_version_is_last":true,"title":["Development of a Real-Time Power/Polarization Monitor using FPGA for Electron Cyclotron Resonance Heating on LHD"],"weko_creator_id":"20","weko_shared_id":-1},"updated":"2023-09-28T05:52:47.012851+00:00"}