{"created":"2023-06-20T15:17:44.640706+00:00","id":11686,"links":{},"metadata":{"_buckets":{"deposit":"26199408-7adb-43c7-9495-4d94138248c3"},"_deposit":{"created_by":20,"id":"11686","owners":[20],"pid":{"revision_id":0,"type":"depid","value":"11686"},"status":"published"},"_oai":{"id":"oai:nifs-repository.repo.nii.ac.jp:00011686","sets":["6:7"]},"author_link":["128142","127170","67177","127151","127314"],"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2023-04-03","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"5","bibliographicPageEnd":"5(August 2023)","bibliographicPageStart":"1","bibliographicVolumeNumber":"33","bibliographic_titles":[{"bibliographic_title":"IEEE Transactions on Applied Superconductivity "}]}]},"item_10001_description_4":{"attribute_name":"著者ID","attribute_value_mlt":[{"subitem_description":"0000-0002-1565-8353","subitem_description_type":"Other"}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Magnetic refrigeration technology is expected to be a highly efficient process at a temperature of around 20 K, which is the hydrogen liquefaction temperature. In magnetic refrigeration, a magnetic field change is applied to a magnetocaloric material (MCM) to obtain a magnetocaloric effect. In addition, since the greater the magnetic field change, the better the cooling characteristics, the magnetic field strength of permanent magnets is insufficient, and the use of superconducting coils that can generate strong magnetic fields with low power consumption is essential. We are researching and developing a static magnetic refrigeration system (SMRS) that does not have moving parts to obtain magnetic field changes, and generates them by altering the energizing current to the coil. The key to devising this system is an AC loss of the superconducting coil. In this study, we measured the AC loss under energization conditions of multiple palm-sized REBCO coils at liquid nitrogen temperature, and calculated the efficiency of the SMRS by improving the accuracy of the analysis method for evaluating the AC loss, based on the results. We report the results and discuss the technical feasibility of SMRS.","subitem_description_type":"Abstract"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"IEEE "}]},"item_10001_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1109/TASC.2023.3263786","subitem_relation_type_select":"DOI"}}]},"item_10001_relation_16":{"attribute_name":"情報源","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"N. Hirano, Y. Onodera, T. Mito, Y. Motoki and A. Kawagoe, \"Basic Research on a Magnetic Refrigeration System for Cooling to Liquid Hydrogen Temperature,\" in IEEE Transactions on Applied Superconductivity, vol. 33, no. 5, pp. 1-5, Aug. 2023, Art no. 4702605, doi: 10.1109/TASC.2023.3263786."}]}]},"item_10001_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"Publisher version"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://doi.org/10.1109/TASC.2023.3263786","subitem_relation_type_select":"DOI"}}]},"item_10001_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"© 2023 IEEE. "},{"subitem_rights":"Personal use of this material is permitted. "},{"subitem_rights":"Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. "}]},"item_10001_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA10791666 ","subitem_source_identifier_type":"NCID"}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1051-8223 ","subitem_source_identifier_type":"ISSN"}]},"item_10001_text_23":{"attribute_name":"NAIS","attribute_value_mlt":[{"subitem_text_value":"13763"}]},"item_10001_text_25":{"attribute_name":"書誌的事項","attribute_value_mlt":[{"subitem_text_value":"Article Sequence Number: 4702605 "}]},"item_10001_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"HIRANO, Naoki"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"ONODERA, Yuta"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"MITO, Toshiyuki"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"MOTOKI, Yuta"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"KAWAGOE, Akifumi"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2023-04-28"}],"displaytype":"detail","filename":"13763_IEEE_Trans.Appl.Supercond.pdf","filesize":[{"value":"924.6 kB"}],"format":"application/pdf","licensetype":"license_6","mimetype":"application/pdf","url":{"label":"13763_IEEE_Trans.Appl.Supercond","url":"https://nifs-repository.repo.nii.ac.jp/record/11686/files/13763_IEEE_Trans.Appl.Supercond.pdf"},"version_id":"5eb23de9-1c24-4796-ada8-adf574c0f0f9"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Loss measurement","subitem_subject_scheme":"Other"},{"subitem_subject":"Superconducting magnets","subitem_subject_scheme":"Other"},{"subitem_subject":"Magnetic fields","subitem_subject_scheme":"Other"},{"subitem_subject":"Refrigeration","subitem_subject_scheme":"Other"},{"subitem_subject":"Magnetic shielding","subitem_subject_scheme":"Other"},{"subitem_subject":"Magnetic noise","subitem_subject_scheme":"Other"},{"subitem_subject":"Yttrium barium copper oxide","subitem_subject_scheme":"Other"},{"subitem_subject":"Magnetic refrigeration","subitem_subject_scheme":"Other"},{"subitem_subject":"liquid hydrogen","subitem_subject_scheme":"Other"},{"subitem_subject":"AC loss","subitem_subject_scheme":"Other"},{"subitem_subject":"HTS magnet","subitem_subject_scheme":"Other"},{"subitem_subject":"Norris's expression","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Basic Research on a Magnetic Refrigeration System for Cooling to Liquid Hydrogen Temperature","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Basic Research on a Magnetic Refrigeration System for Cooling to Liquid Hydrogen Temperature"}]},"item_type_id":"10001","owner":"20","path":["7"],"pubdate":{"attribute_name":"公開日","attribute_value":"2023-04-28"},"publish_date":"2023-04-28","publish_status":"0","recid":"11686","relation_version_is_last":true,"title":["Basic Research on a Magnetic Refrigeration System for Cooling to Liquid Hydrogen Temperature"],"weko_creator_id":"20","weko_shared_id":-1},"updated":"2023-09-01T00:52:31.142178+00:00"}