{"created":"2023-06-20T15:07:54.812564+00:00","id":129,"links":{},"metadata":{"_buckets":{"deposit":"6a34ac4f-a025-4ec9-be8f-543c591c008f"},"_deposit":{"created_by":3,"id":"129","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"129"},"status":"published"},"_oai":{"id":"oai:nifs-repository.repo.nii.ac.jp:00000129","sets":["6:7"]},"author_link":["66788","66794","66791","66792","66787","66790","66793","66789"],"item_2_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2010-01-01","bibliographicIssueDateType":"Issued"},"bibliographicPageStart":"S2098-1 - S2098-4","bibliographicVolumeNumber":"Vol.5","bibliographic_titles":[{},{"bibliographic_title":"Plasma and Fusion Research","bibliographic_titleLang":"en"}]}]},"item_2_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"We have developed a compact electron spectrometer (ESM) to investigate ignition mechanism in the Fast Ignition Realization Experiment project. Hot electrons, produced by the irradiation of a gold target by using a compressed chirped pulse laser, are used for auxiliary heating of the imploded core. An imaging plate is used as the electron detector for medical purposes. However, the relationship between the beam intensity and the detector signal is not clear. The ESM should be calibrated because it is highly compact and has a complex magnetic field for bending caused by installation in a limited space. We have performed the calibration by using an L-band LINAC at the Institute of Scientific and Industrial Research, Osaka University, in order to obtain an accurate electron spectrum. The calibration used a single electron pulse at two different energies, 9.5 MeV and 27.1 MeV, with 0.1-10 pC. The energy spreads are 0.2 MeV at 9.5 MeV and 0.3 MeV at 27.1 MeV. The analyzer has been tested to measure energetic electrons from plain and integrated targets irradiated by the Laser or Fast Ignition Experiment (maximum energy of 10 kJ) up to 800 J.","subitem_description_type":"Abstract"}]},"item_2_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"プラズマ・核融合学会"}]},"item_2_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1585/pfr.5.S2098","subitem_relation_type_select":"DOI"}}]},"item_2_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"? 2010 The Japan Society of Plasma Science and Nuclear Fusion Research"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"OZAKI, Tetsuo","creatorNameLang":"en"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"KOGA, Mayuko","creatorNameLang":"en"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"SHIRAGA, Hiroyuki","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"KATO, Ryuko","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"KASHIWAGI, Shigeru","creatorNameLang":"en"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"ISOYAMA, Goro","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"SAKAGAMI, Hitoshi","creatorNameLang":"en"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"FIREX, GROUP","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2016-03-11"}],"displaytype":"detail","filename":"pfr2010_05-S2098.pdf","filesize":[{"value":"762.6 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"pfr2010_05-S2098.pdf","url":"https://nifs-repository.repo.nii.ac.jp/record/129/files/pfr2010_05-S2098.pdf"},"version_id":"33087d6f-1284-4fa4-a0f9-67a3e2b68900"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"ESM","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"calibration","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"LINAC","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"electron","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"FIREX","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"IP","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Gekko XII","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"LFEX","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"energy spectrum","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Calibration of Compact Electron Spectrometer for the FIREX-I Project in Gekko XII","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Calibration of Compact Electron Spectrometer for the FIREX-I Project in Gekko XII","subitem_title_language":"en"}]},"item_type_id":"2","owner":"3","path":["7"],"pubdate":{"attribute_name":"公開日","attribute_value":"2011-05-06"},"publish_date":"2011-05-06","publish_status":"0","recid":"129","relation_version_is_last":true,"title":["Calibration of Compact Electron Spectrometer for the FIREX-I Project in Gekko XII"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2024-04-24T06:43:04.833127+00:00"}