@article{oai:nifs-repository.repo.nii.ac.jp:02000457, author = {BUI, Xuan Nhat Son and MATSUURA, Hiroto and HAYASHI, Yuki and NAGAOKA, Kenichi and NAGAOKA, Ken-ichi and MASUZAKI, Suguru}, issue = {3}, journal = {Review of Scientific Instruments}, month = {Mar}, note = {ORCID 0009-0005-6662-7935, To keep the tritium breeding rate TBR > 1 and to meet the high heat load and neutron shielding requirements for the first wall and divertor in fusion demonstration (DEMO) reactors, the number of port plugs and other openings must be limited. To accomplish this, it is necessary to develop alternatives to the use of infrared (IR) hermography to determine the peak heat flux and the heat flux profile onto divertor targets. A divertor tile equipped with multiple temperature monitoring channels can be used to reproduce the temperature profile. To avoid the high temperatures and high neutron flux environment in a DEMO, the monitoring positions can be set well away from the irradiated surface. However, the spatial resolution of this method is lower than that provided by IR thermography. In the present work, we apply twodimensional temperature response functions and the corresponding heat conduction model to temperature data obtained from a divertor tile surface in the large helical device to study the effects of the spatial resolution of the monitored temperature profile on the reconstructed heat flux profile. The findings provide information that will be useful in defining a method for embedding thermocouples into the divertor tiles of future DEMO reactors.}, title = {Application of two-dimensional temperature response functions for reconstruction of divertor heat flux profile in commercial fusion reactors}, volume = {95}, year = {2024} }