@article{oai:nifs-repository.repo.nii.ac.jp:00000330, author = {SHIMOZUMA, Takashi and TAKAHASHI, Hiromi and KUBO, Shin and YOSHIMURA, Yasuo and IGAMI, Hiroe and NISHIURA, Masaki and OGASAWARA, Shinya and MAKINO, Ryohei and IDEI, Hiroshi and MARUSHCHENKO, Nikolai B and TURKIN, Yuri and MUTOH, Takashi}, journal = {Plasma and Fusion Research}, month = {Jun}, note = {High harmonic electron cyclotron resonance heating (ECH) can extend the plasma heating region to higher density and higher β compared to the normal heating scenario. In this study, the heating characteristics of the second-harmonic ordinary (O2) and third-harmonic extraordinary (X3) modes and the possible extension of heating regime are experimentally confirmed. At the same time, a comparative study using ray-tracing calculation was performed in the realistic three-dimensional configuration of the Large Helical Device. The O2 mode heating showed a 40% absorption rate even above the X2 mode cut-off density. The X3 mode heating using powerful 77 GHz gyrotrons demonstrated an increase of about 40% in the central electron temperature in the plasmas at β-value of about 1%. These results were quantitatively explained to some extent by ray-tracing calculations.}, title = {High Harmonic ECH Experiment for Extension of Heating Parameter Regime in LHD}, volume = {Vol.8}, year = {2013} }