{"created":"2023-06-20T15:08:12.995573+00:00","id":501,"links":{},"metadata":{"_buckets":{"deposit":"9b3e8ab5-15bf-4888-b651-f2dbfec1685e"},"_deposit":{"created_by":3,"id":"501","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"501"},"status":"published"},"_oai":{"id":"oai:nifs-repository.repo.nii.ac.jp:00000501","sets":["6:7"]},"author_link":["124666","124667"],"item_2_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2012-02-01","bibliographicIssueDateType":"Issued"},"bibliographicPageStart":"2405009","bibliographicVolumeNumber":"7","bibliographic_titles":[{"bibliographic_title":"Plasma and Fusion Research"}]}]},"item_2_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"o understand the conditions of exhaust gas treatment at the transition point between the Large Helical Device (LHD) vacuum pumping system and the exhaust gas tritium recovery system, the gas flow rate and hydrogen concentration were measured. Simultaneous measurement of the exhaust gas flow rate and hydrogen concentration was made possible by applying two types of hydrogen monitors: a thermal conductivity sensor and a combustible gas sensor. The obtained results have led to remodeling of the LHD vacuum pumping system and an optimised plan of operation for the tritium recovery system.","subitem_description_type":"Abstract"}]},"item_2_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"The Japan Society of Plasma Science and Nuclear Fusion Research"}]},"item_2_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"info:doi/10.1585/pfr.7.2405009","subitem_relation_type_select":"DOI"}}]},"item_2_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"Publisher version"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1585/pfr.7.2405009","subitem_relation_type_select":"DOI"}}]},"item_2_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"(a) 2012 The Japan Society of Plasma Science and Nuclear Fusion Research"}]},"item_2_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA12346675","subitem_source_identifier_type":"NCID"}]},"item_2_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"18806821","subitem_source_identifier_type":"ISSN"}]},"item_2_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"ASAKURA, Yamato","creatorNameLang":"en"}],"familyNames":[{}],"givenNames":[{}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"SUZUKI, Naoyuki","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2016-03-23"}],"displaytype":"detail","filename":"pfr2012_07-2405009.pdf","filesize":[{"value":"2.4 MB"}],"format":"application/pdf","licensetype":"license_6","mimetype":"application/pdf","url":{"label":"pfr2012_07-2405009.pdf","url":"https://nifs-repository.repo.nii.ac.jp/record/501/files/pfr2012_07-2405009.pdf"},"version_id":"db0b1dcb-1437-4f50-affa-b6827de90bd3"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"tritium","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"hydrogen monitor","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"tritium recovery","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"vacuum pumping","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"exhaust gas","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"large helical device","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Planned Operation of Tritium Recovery System Based on Investigation of LHD Exhaust System","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Planned Operation of Tritium Recovery System Based on Investigation of LHD Exhaust System"}]},"item_type_id":"2","owner":"3","path":["7"],"pubdate":{"attribute_name":"公開日","attribute_value":"2012-07-30"},"publish_date":"2012-07-30","publish_status":"0","recid":"501","relation_version_is_last":true,"title":["Planned Operation of Tritium Recovery System Based on Investigation of LHD Exhaust System"],"weko_creator_id":"3","weko_shared_id":3},"updated":"2023-12-21T00:57:59.431217+00:00"}