{"created":"2023-06-20T15:15:56.325273+00:00","id":9585,"links":{},"metadata":{"_buckets":{"deposit":"877962a3-d132-4fce-8950-4d97d32730ff"},"_deposit":{"created_by":3,"id":"9585","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"9585"},"status":"published"},"_oai":{"id":"oai:nifs-repository.repo.nii.ac.jp:00009585","sets":["8:32"]},"author_link":["58026","58030","58031","58029","58027","58028"],"item_5_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1996-03-01","bibliographicIssueDateType":"Issued"},"bibliographic_titles":[{},{"bibliographic_title":"Research Report NIFS-Series","bibliographic_titleLang":"en"}]}]},"item_5_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"\"An emittance meter is developed using pepper-pot method. Kapton foils are used to detect intensity distributions of small beamlets at the \"\"image\"\" plane of the pepper-pot. Emittance of H^- beams from a large plasma source for the neutral beam injector of the Large Helical Device (LHD) has been measured The normalized emittance (95%) of a 6 mA H^- beam with emission current density of about 10 mA/cm^2 is ~ 0.59 mm mrad. The present system is very simple, and it eliminates many complexities of the existing schemes.\"","subitem_description_type":"Abstract"}]},"item_5_source_id_10":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0915-633X","subitem_source_identifier_type":"ISSN"}]},"item_5_text_8":{"attribute_name":"報告書番号","attribute_value_mlt":[{"subitem_text_value":"NIFS-405"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"\"Guharay, S.K.","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Tsumori, K.","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Hamabe, M.","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Takeiri, Y.","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Kaneko, O.","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Kuroda, T.\"","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"H^- beam","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"neutral beam injector","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"emittance measurements","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"pepper-pot method","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Kapton foil detector","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"research report","resourceuri":"http://purl.org/coar/resource_type/c_18ws"}]},"item_title":"Simple Emittance Measurement of H- Beams from a Large Plasma Source","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Simple Emittance Measurement of H- Beams from a Large Plasma Source","subitem_title_language":"en"}]},"item_type_id":"5","owner":"3","path":["32"],"pubdate":{"attribute_name":"公開日","attribute_value":"2010-02-05"},"publish_date":"2010-02-05","publish_status":"0","recid":"9585","relation_version_is_last":true,"title":["Simple Emittance Measurement of H- Beams from a Large Plasma Source"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-06-20T20:57:48.221608+00:00"}