{"created":"2023-06-20T15:16:02.154569+00:00","id":9685,"links":{},"metadata":{"_buckets":{"deposit":"0b836f24-cd87-49e8-9415-4c0fa23391e4"},"_deposit":{"created_by":3,"id":"9685","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"9685"},"status":"published"},"_oai":{"id":"oai:nifs-repository.repo.nii.ac.jp:00009685","sets":["8:32"]},"author_link":["68924","68925","68923","68926","68922"],"item_5_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1996-02-01","bibliographicIssueDateType":"Issued"},"bibliographic_titles":[{},{"bibliographic_title":"Research Report NIFS-Series","bibliographic_titleLang":"en"}]}]},"item_5_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"A new charge exchange spectroscopic technique using a Fabry-Perot spectrometer has been developed to increase the photon flux at the detector and improve the time resolution of ion temperature and plasma rotation velocity measurements. The spectral resolution is obtained by arranging two dimensional fiber optics and a two dimensional detector at the focal plane of a coupled lens located on both sides of a Fabry-Perot spectrometer. The effective finesse of the Fabry-Perot interferometer in this system is 14. The time evolution of the ion temperature is obtained with a time resolution of 125 mu s and with the spatial resolution of 3 cm (8channels).","subitem_description_type":"Abstract"}]},"item_5_source_id_10":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0915-633X","subitem_source_identifier_type":"ISSN"}]},"item_5_text_8":{"attribute_name":"報告書番号","attribute_value_mlt":[{"subitem_text_value":"NIFS-401"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Ida, K.","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Xu, J","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Sato, K.N.","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Sakakita, H.","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"JIPP TII-U Group, ","creatorNameLang":"en"}],"familyNames":[{"familyName":"JIPP TII-U Group","familyNameLang":"en"}],"givenNames":[{"givenName":"","givenNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2016-03-11"}],"displaytype":"detail","filename":"NIFS-401.pdf","filesize":[{"value":"429.0 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"NIFS-401.pdf","url":"https://nifs-repository.repo.nii.ac.jp/record/9685/files/NIFS-401.pdf"},"version_id":"50ed13ee-e4b7-4931-9479-df6e3507f1d4"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"research report","resourceuri":"http://purl.org/coar/resource_type/c_18ws"}]},"item_title":"Fast Charge Exchange Spectroscopy Using a Fabry-Perot Spectrometer in the JIPP TII-U Tokamak","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Fast Charge Exchange Spectroscopy Using a Fabry-Perot Spectrometer in the JIPP TII-U Tokamak","subitem_title_language":"en"}]},"item_type_id":"5","owner":"3","path":["32"],"pubdate":{"attribute_name":"公開日","attribute_value":"2009-02-26"},"publish_date":"2009-02-26","publish_status":"0","recid":"9685","relation_version_is_last":true,"title":["Fast Charge Exchange Spectroscopy Using a Fabry-Perot Spectrometer in the JIPP TII-U Tokamak"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-12-11T04:21:33.994621+00:00"}