{"created":"2023-06-20T15:16:15.709408+00:00","id":9952,"links":{},"metadata":{"_buckets":{"deposit":"a7b64802-1d20-428e-b53d-35ee001259b9"},"_deposit":{"created_by":3,"id":"9952","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"9952"},"status":"published"},"_oai":{"id":"oai:nifs-repository.repo.nii.ac.jp:00009952","sets":["8:32"]},"author_link":["61028","61030","61026","61027","61031","61032","61033","61035","61029","61034"],"item_5_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1991-06-01","bibliographicIssueDateType":"Issued"},"bibliographic_titles":[{},{"bibliographic_title":"Research Report NIFS-Series","bibliographic_titleLang":"en"}]}]},"item_5_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"\"The dependence of the energy confinement time tau_E in the H-mode discharges on the plasma elongation and divertor configurations is studied. Regression analysis is made on the H-mode database, while the dependence on the closed/open divertor is introduced according to the ASDEX experiments. The dependence of tau_ E on the elongation factor kappa was found to be positive (approximately kappa^0.8) for the ELM free H-mode, confirming the experiments on kappa-dependence in JFT-2M tokamak. The influence of the single/double null divertor configuration is also discussed.\"","subitem_description_type":"Abstract"}]},"item_5_source_id_10":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0915-633X","subitem_source_identifier_type":"ISSN"}]},"item_5_text_8":{"attribute_name":"報告書番号","attribute_value_mlt":[{"subitem_text_value":"NIFS-093"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"\"Miura, Y.","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Itoh, K.","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Itoh, S -I.","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Takizuka, T.","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Tamai, H.","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Matsuda, T.","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Suzuki, N.","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Mori, M.","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Maeda, H.","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Kardaun, O.\"","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Energy Confinement Time","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Scaling Law","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"H-Mode Elongation","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Single-Null and Double-Null Divertor","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Closed and Open Divertor","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"research report","resourceuri":"http://purl.org/coar/resource_type/c_18ws"}]},"item_title":"Geometric Dependence of the Scaling Law on the Energy Confinement Time in H-mode Discharges","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Geometric Dependence of the Scaling Law on the Energy Confinement Time in H-mode Discharges","subitem_title_language":"en"}]},"item_type_id":"5","owner":"3","path":["32"],"pubdate":{"attribute_name":"公開日","attribute_value":"2010-02-05"},"publish_date":"2010-02-05","publish_status":"0","recid":"9952","relation_version_is_last":true,"title":["Geometric Dependence of the Scaling Law on the Energy Confinement Time in H-mode Discharges"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-06-20T20:55:05.127688+00:00"}