WEKO3
-
RootNode
アイテム
Calibration Source for Electron Cyclotron Emission Measurements
http://hdl.handle.net/10655/3176
http://hdl.handle.net/10655/3176b36bb4d6-f40a-4ae9-a131-7ec20db0b092
Item type | 研究報告書 / Research Paper(1) | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
公開日 | 2010-02-05 | |||||||||||||||
タイトル | ||||||||||||||||
タイトル | Calibration Source for Electron Cyclotron Emission Measurements | |||||||||||||||
言語 | en | |||||||||||||||
言語 | ||||||||||||||||
言語 | eng | |||||||||||||||
キーワード | ||||||||||||||||
言語 | en | |||||||||||||||
主題Scheme | Other | |||||||||||||||
主題 | calibration source | |||||||||||||||
キーワード | ||||||||||||||||
言語 | en | |||||||||||||||
主題Scheme | Other | |||||||||||||||
主題 | electron cyclotron emission | |||||||||||||||
キーワード | ||||||||||||||||
言語 | en | |||||||||||||||
主題Scheme | Other | |||||||||||||||
主題 | grating polychromator | |||||||||||||||
キーワード | ||||||||||||||||
言語 | en | |||||||||||||||
主題Scheme | Other | |||||||||||||||
主題 | electron temperature | |||||||||||||||
キーワード | ||||||||||||||||
言語 | en | |||||||||||||||
主題Scheme | Other | |||||||||||||||
主題 | tokamak plasma | |||||||||||||||
資源タイプ | ||||||||||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_18ws | |||||||||||||||
資源タイプ | research report | |||||||||||||||
アクセス権 | ||||||||||||||||
アクセス権 | metadata only access | |||||||||||||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||||||||||||
著者 |
"Kawahata, K.
× "Kawahata, K.
× Sakamoto, M.
× Fujita, J.
× Matsuo, H.
× Sakai, K."
|
|||||||||||||||
抄録 | ||||||||||||||||
内容記述タイプ | Abstract | |||||||||||||||
内容記述 | A high temperature radiation source has been developed for the absolute calibration of diagnostic instruments for measuring electron cyclotron emission from high temperature plasmas. The source has a radiation area of phi150 mm and can be heated up to 500 degrees C. The measured emissivity of the source is close to unity in the wavelength region between 0.5 and 5 mm . The grating polychromator has been calibrated using the radiation source developed. The obtained temperatures agree with those by the pulse height analysis of soft X-rays and Thomson scattering measurement within 10 %. | |||||||||||||||
書誌情報 |
en : Research Report NIFS-Series 発行日 1990-02-01 |
|||||||||||||||
報告書番号 | ||||||||||||||||
NIFS-019 | ||||||||||||||||
ISSN | ||||||||||||||||
収録物識別子タイプ | ISSN | |||||||||||||||
収録物識別子 | 0915-633X |
Share
Cite as
"Kawahata, K., Sakamoto, M., Fujita, J., Matsuo, H., Sakai, K.", 1990, Calibration Source for Electron Cyclotron Emission Measurements.
Loading...