{"_buckets": {"deposit": "21754201-d522-454e-8b4c-6296a4caebb1"}, "_deposit": {"created_by": 3, "id": "486", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "486"}, "status": "published"}, "_oai": {"id": "oai:nifs-repository.repo.nii.ac.jp:00000486", "sets": ["7"]}, "author_link": ["124552", "124555", "124556", "124551", "124553", "124554"], "item_2_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2010-01-01", "bibliographicIssueDateType": "Issued"}, "bibliographicPageStart": "S2052-1 -S2052-4", "bibliographicVolumeNumber": "Vol.5", "bibliographic_titles": [{}, {"bibliographic_title": "Plasma and Fusion Research", "bibliographic_titleLang": "en"}]}]}, "item_2_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Parallel ion flow velocity along a magnetic field has been measured using a laser induced fluorescence (LIF) method in an electron cyclotron resonance (ECR) argon plasma with a weakly-diverging magnetic field. To measure parallel flow velocity in a cylindrical plasma using the LIF method, the laser beam should be injected along device axis; however, the reflection of the incident beam causes interference between the LIF emission of the incident and reflected beams. Here we present a method of quasi-parallel laser injection at a small angle, which utilizes the reflected beam as well as the incident beam to obtain the parallel ion flow velocity. Using this method, we observed an increase in parallel ion flow velocity along the magnetic field. The acceleration mechanism is briefly discussed on the basis of the ion fluid model.", "subitem_description_type": "Abstract"}]}, "item_2_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "プラズマ・核融合学会"}]}, "item_2_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1585/pfr.5.S2052", "subitem_relation_type_select": "DOI"}}]}, "item_2_rights_15": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "? 2010 The Japan Society of Plasma Science and Nuclear Fusion Research"}]}, "item_2_text_24": {"attribute_name": "登録情報", "attribute_value_mlt": [{"subitem_text_value": "Submitted by Kanae Hashimoto (kanae@nifs.ac.jp) on 2011-05-02T05:04:43Z\nNo. of bitstreams: 1\npfr2010_05-S2052.pdf: 584276 bytes, checksum: 2a295572211dfb567410df50b6318269 (MD5)@@@Made available in DSpace on 2011-05-02T05:04:52Z (GMT). No. of bitstreams: 1\npfr2010_05-S2052.pdf: 584276 bytes, checksum: 2a295572211dfb567410df50b6318269 (MD5)\n Previous issue date: 2010"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "YOSHIMURA, Shinji", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "124551", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "OKAMOTO, Atsushi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "124552", "nameIdentifierScheme": "WEKO"}]}, {"creatorAffiliations": [{"affiliationNameIdentifiers": [{"affiliationNameIdentifier": "", "affiliationNameIdentifierScheme": "ISNI", "affiliationNameIdentifierURI": "http://www.isni.org/isni/"}], "affiliationNames": [{"affiliationName": "", "affiliationNameLang": "ja"}]}], "creatorNames": [{"creatorName": "TERASAKA, Kenichiro", "creatorNameLang": "en"}], "familyNames": [{"familyName": "TERASAKA", "familyNameLang": "en"}], "givenNames": [{"givenName": " Kenichiro", "givenNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "124553", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "OGIWARA, Kohei", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "124554", "nameIdentifierScheme": "WEKO"}]}, {"creatorAffiliations": [{"affiliationNameIdentifiers": [{"affiliationNameIdentifier": "", "affiliationNameIdentifierScheme": "ISNI", "affiliationNameIdentifierURI": "http://www.isni.org/isni/"}], "affiliationNames": [{"affiliationName": "", "affiliationNameLang": "ja"}]}], "creatorNames": [{"creatorName": "ARAMAKI, Mitsutoshi", "creatorNameLang": "en"}], "familyNames": [{"familyName": "ARAMAKI", "familyNameLang": "en"}], "givenNames": [{"givenName": " Mitsutoshi", "givenNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "124555", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "TANAKA, Masayoshi Y.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "124556", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2016-03-23"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "pfr2010_05-S2052.pdf", "filesize": [{"value": "584.3 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 584300.0, "url": {"label": "pfr2010_05-S2052.pdf", "url": "https://nifs-repository.repo.nii.ac.jp/record/486/files/pfr2010_05-S2052.pdf"}, "version_id": "c0c28011-48e5-430d-9010-5b939bed1bbf"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "ion flow", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "flow velocity measurement", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "laser induced fluorescence", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "tunable dye laser", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "metastable argon ion", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "diverging magnetic field", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "ion acceleration", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "ECR plasma", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Parallel Ion Flow Velocity Measurement Using Laser Induced Fluorescence Method in an Electron Cyclotron Resonance Plasma", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Parallel Ion Flow Velocity Measurement Using Laser Induced Fluorescence Method in an Electron Cyclotron Resonance Plasma", "subitem_title_language": "en"}]}, "item_type_id": "2", "owner": "3", "path": ["7"], "permalink_uri": "http://hdl.handle.net/10655/6396", "pubdate": {"attribute_name": "公開日", "attribute_value": "2011-05-02"}, "publish_date": "2011-05-02", "publish_status": "0", "recid": "486", "relation": {}, "relation_version_is_last": true, "title": ["Parallel Ion Flow Velocity Measurement Using Laser Induced Fluorescence Method in an Electron Cyclotron Resonance Plasma"], "weko_shared_id": -1}
Parallel Ion Flow Velocity Measurement Using Laser Induced Fluorescence Method in an Electron Cyclotron Resonance Plasma
http://hdl.handle.net/10655/6396
http://hdl.handle.net/10655/6396e3a04e3e-9ad6-4204-8510-63d7d593b857
名前 / ファイル | ライセンス | アクション |
---|---|---|
pfr2010_05-S2052.pdf (584.3 kB)
|
|
Item type | 学術雑誌論文 / Journal Article_02(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2011-05-02 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Parallel Ion Flow Velocity Measurement Using Laser Induced Fluorescence Method in an Electron Cyclotron Resonance Plasma | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | ion flow | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | flow velocity measurement | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | laser induced fluorescence | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | tunable dye laser | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | metastable argon ion | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | diverging magnetic field | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | ion acceleration | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | ECR plasma | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
YOSHIMURA, Shinji
× YOSHIMURA, Shinji× OKAMOTO, Atsushi× TERASAKA, Kenichiro× OGIWARA, Kohei× ARAMAKI, Mitsutoshi× TANAKA, Masayoshi Y. |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Parallel ion flow velocity along a magnetic field has been measured using a laser induced fluorescence (LIF) method in an electron cyclotron resonance (ECR) argon plasma with a weakly-diverging magnetic field. To measure parallel flow velocity in a cylindrical plasma using the LIF method, the laser beam should be injected along device axis; however, the reflection of the incident beam causes interference between the LIF emission of the incident and reflected beams. Here we present a method of quasi-parallel laser injection at a small angle, which utilizes the reflected beam as well as the incident beam to obtain the parallel ion flow velocity. Using this method, we observed an increase in parallel ion flow velocity along the magnetic field. The acceleration mechanism is briefly discussed on the basis of the ion fluid model. | |||||
書誌情報 |
en : Plasma and Fusion Research 巻 Vol.5, p. S2052-1 -S2052-4, 発行日 2010-01-01 |
|||||
出版者 | ||||||
出版者 | プラズマ・核融合学会 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1585/pfr.5.S2052 | |||||
権利 | ||||||
権利情報 | ? 2010 The Japan Society of Plasma Science and Nuclear Fusion Research |