{"_buckets": {"deposit": "5fd0fc31-36f8-4679-a016-b7b4c2b7306b"}, "_deposit": {"created_by": 3, "id": "496", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "496"}, "status": "published"}, "_oai": {"id": "oai:nifs-repository.repo.nii.ac.jp:00000496", "sets": ["7"]}, "author_link": ["124632", "124633", "124635", "124637", "124636", "124634"], "item_2_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2012-10-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "Issue10", "bibliographicPageStart": "10D920-1 - 10D920-3", "bibliographicVolumeNumber": "Vol.83", "bibliographic_titles": [{}, {"bibliographic_title": "Review of Scientific Instruments", "bibliographic_titleLang": "en"}]}]}, "item_2_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The particle loss in a helical plasma can be found by measuring the angular distribution of the energetic neutral particles using the angularly resolved multi-sightline neutral particle analyzer (ARMS). In ARMS, the AXUV detector with 20 segments usually used as UV monitor is utilized as the particle detector. Two ARMSs, which are installed with perpendicular and tangential views are operated for measuring the real time neutral particle distribution and investigating the particle loss.", "subitem_description_type": "Abstract"}]}, "item_2_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "American Institute of Physics"}]}, "item_2_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1063/1.4742925", "subitem_relation_type_select": "DOI"}}]}, "item_2_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "Publisher version"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1063/1.4742925", "subitem_relation_type_select": "DOI"}}]}, "item_2_rights_15": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "(c) 2012 American Institute of Physics"}]}, "item_2_text_24": {"attribute_name": "登録情報", "attribute_value_mlt": [{"subitem_text_value": "Submitted by Kanae Hashimoto (kanae@nifs.ac.jp) on 2013-02-25T01:21:27ZNo. of bitstreams: 1RevSciInstrum_83_10D920.pdf: 1141737 bytes, checksum: cf81317e2a427532bcac3bb9c34092ae (MD5)@@@Made available in DSpace on 2013-02-25T01:21:41Z (GMT). No. of bitstreams: 1RevSciInstrum_83_10D920.pdf: 1141737 bytes, checksum: cf81317e2a427532bcac3bb9c34092ae (MD5)  Previous issue date: 2012-10"}]}, "item_2_version_type_20": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Ozaki,  T.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "124632", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Veshchev,  E.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "124633", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ido,  T.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "124634", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shimizu,  A.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "124635", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Goncharov,  P.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "124636", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sudo,  S.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "124637", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2016-03-23"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "RevSciInstrum_83_10D920.pdf", "filesize": [{"value": "1.1 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_11", "mimetype": "application/pdf", "size": 1100000.0, "url": {"label": "RevSciInstrum_83_10D920.pdf", "url": "https://nifs-repository.repo.nii.ac.jp/record/496/files/RevSciInstrum_83_10D920.pdf"}, "version_id": "1702a1a3-e67f-4b8a-9875-e6bbaf30725c"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Perpendicular and tangential angularly resolved multi-sight neutral particle analyzer system in LHD", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Perpendicular and tangential angularly resolved multi-sight neutral particle analyzer system in LHD"}]}, "item_type_id": "2", "owner": "3", "path": ["7"], "permalink_uri": "http://hdl.handle.net/10655/10139", "pubdate": {"attribute_name": "公開日", "attribute_value": "2013-02-25"}, "publish_date": "2013-02-25", "publish_status": "0", "recid": "496", "relation": {}, "relation_version_is_last": true, "title": ["Perpendicular and tangential angularly resolved multi-sight neutral particle analyzer system in LHD"], "weko_shared_id": 3}
  1. Published Papers
  2. Published Papers

Perpendicular and tangential angularly resolved multi-sight neutral particle analyzer system in LHD

http://hdl.handle.net/10655/10139
http://hdl.handle.net/10655/10139
b9e67158-cfc3-4a7b-8b95-c6e6c33788b7
名前 / ファイル ライセンス アクション
RevSciInstrum_83_10D920.pdf RevSciInstrum_83_10D920.pdf (1.1 MB)
license.icon
Item type 学術雑誌論文 / Journal Article_02(1)
公開日 2013-02-25
タイトル
タイトル Perpendicular and tangential angularly resolved multi-sight neutral particle analyzer system in LHD
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Ozaki, T.

× Ozaki, T.

WEKO 124632

en Ozaki, T.

Search repository
Veshchev, E.

× Veshchev, E.

WEKO 124633

en Veshchev, E.

Search repository
Ido, T.

× Ido, T.

WEKO 124634

en Ido, T.

Search repository
Shimizu, A.

× Shimizu, A.

WEKO 124635

en Shimizu, A.

Search repository
Goncharov, P.

× Goncharov, P.

WEKO 124636

en Goncharov, P.

Search repository
Sudo, S.

× Sudo, S.

WEKO 124637

en Sudo, S.

Search repository
抄録
内容記述タイプ Abstract
内容記述 The particle loss in a helical plasma can be found by measuring the angular distribution of the energetic neutral particles using the angularly resolved multi-sightline neutral particle analyzer (ARMS). In ARMS, the AXUV detector with 20 segments usually used as UV monitor is utilized as the particle detector. Two ARMSs, which are installed with perpendicular and tangential views are operated for measuring the real time neutral particle distribution and investigating the particle loss.
書誌情報 en : Review of Scientific Instruments

巻 Vol.83, 号 Issue10, p. 10D920-1 - 10D920-3, 発行日 2012-10-01
出版者
出版者 American Institute of Physics
DOI
関連タイプ isIdenticalTo
識別子タイプ DOI
関連識別子 10.1063/1.4742925
権利
権利情報 (c) 2012 American Institute of Physics
関連サイト
識別子タイプ DOI
関連識別子 https://doi.org/10.1063/1.4742925
関連名称 Publisher version
著者版フラグ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
戻る
0
views
See details
Views

Versions

Ver.1 2023-06-20 16:21:07.551008
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3